Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00884838091429), received between May 26, 2026 and Sep 30, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (2 reports).

3 other recalls cover devices cleared under the same FDA submission (K153022); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 4 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings2
  • Application Program Problem1
  • Failure to Transmit Record1
  • Output Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Incorrect, Inadequate or Imprecise Result or Readings

    Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user was reported that DICOM import crashed occasionally as there was a PDFClinicalContentExecuter error.. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this constitutes a reportable malfunction.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50944390 ↗
  • MalfunctionSep 21, 2026Incorrect, Inadequate or Imprecise Result or Readings

    Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein user could not retrieve a study. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this constitutes a reportable malfunction.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50841476 ↗
  • MalfunctionSep 17, 2026Failure to Transmit Record

    Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein thumbnails bar said user was unable to retrieve the lost study. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this constitutes a reportable malfunction.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50799227 ↗
  • MalfunctionSep 16, 2026Output Problem

    Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user found a vulnerability in ISCV 3.2.1 that permits anyone to login to ISCV without a password through a Universal Resource Locator (URL) . The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this constitutes a reportable malfunction.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50786948 ↗
  • MalfunctionMay 26, 2026Application Program Problem

    IT WAS REPORTED TO PHILIPS THAT A USER WAS UNABLE TO SAVE CHANGES TO A REPORT AN ERROR WAS RECEIVED. THE DEVICE WAS IN CLINICAL USE AT THE TIME OF THE EVENT, AND NO ADVERSE EVENTS OR HARM WERE REPORTED IN THE COMPLAINT. BASED ON THE RESULTS OF THE ANALYSIS, IT WAS DETERMINED THAT THE PRODUCT HAS MALFUNCTIONED AND THE CAUSE OF THE REPORTED PROBLEM WAS A 'NAN' (NOT A NUMBER) VALUE IN THE XML FILE GENERATED BY DCMIMPORT. INTELLISPACE CARDIOVASCULAR (ISCV) GENERATED AN ERROR AS IT WAS UNABLE TO PROCESS THIS VALUE. AS AN IMMEDIATE ACTION, THE ISSUE WAS RESOLVED BY EDITING OUT THE NAN VALUE IN D:\ANALYSYSBOX FOLDER. ALTHOUGH NO ADVERSE EVENTS OR PATIENT HARM WERE REPORTED IN THE ASSOCIATED COMPLAINT, THIS MALFUNCTION HAS BEEN DETERMINED TO BE REPORTABLE. UNDER SPECIFIC CIRCUMSTANCES, IT COULD POTENTIALLY LEAD TO DELAYED DIAGNOSIS OR MISDIAGNOSIS. GIVEN THE DEFECT¿S NATURE AND ITS POTENTIAL IMPACT ON CLINICAL DECISION-MAKING IF IT WERE TO RECUR, PHILIPS HAS DETERMINED THAT THIS CONSTITUTES A REPORTABLE MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25274026 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K153022. One submission often covers many models, so check the product and lot details in each record.

  • Z-2543-2025 · Aug 8, 2025 · Open, Classified
    IntelliSpace Cardiovascular, Software 8.0.0.4.
  • Z-1740-2025 · Apr 7, 2025 · Open, Classified
    IntelliSpace Cardiovascular software versions 6.x, 7.x, and 8.x; Model Number: 830089.
  • Z-1252-2025 · Apr 4, 2024 · Open, Classified
    Philips IntelliSpace Cardiovascular software, Model 830089.