Pro-Line® CT MR28037201Recalls & reported problems
Medical Components, Inc. · 7F X 60CM DUAL LUMEN PRO-LINE® CT BASIC IR SET · Class 2 · Implant
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00884908034646), received between Feb 7, 2018 and Mar 25, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Leak/Splash” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Leak/Splash2
Patient problems
- No Known Impact Or Consequence To Patient1
- Thrombosis/Thrombus1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 25, 2024Leak/Splash; Leak/Splash
THE PATIENT WAS UNDERGOING A BONE MARROW TRANSPLANT. CENTRAL LINE INSERTED. BLOOD LOSS NOTED FROM TUNNEL. ULTRASOUND SHOWED RIGHT JUGULAR VEIN THROMBOSIS. CT OF THE CHEST SHOWED AN INCREASE IN DIAMETER OF THE RIGHT INTERNAL JUGULAR VEIN AND THE LUMEN IS OCCUPIED BY MATERIAL INHOMOGENEOUS, SPONTANEOUSLY HYPERDENSE ON BASAL SCANS AND IT ITS CONTEXT SMALL GAS BUBBLES, INDICATIVE OF THROMBUS. ANTICOAGULANT THERAPY STARTED WITH LOW MOLECULAR WEIGHT HEPARIN. CATHETER WAS REMOVED AND FOUND TO HAVE A FISSURE.
Patient problems: Thrombosis/Thrombus
MAUDE report 18969777 ↗InjuryFeb 7, 2018Leak/Splash; Leak/Splash
THREE WEEKS POST INSERTION THE PATIENT WAS IN CT SCAN TO HAVE A CONTRAST COMPUTED TOMOGRAPHY ANGIOGRAPHY (CTA) DONE. UPON ADMINISTRATION OF CONTRAST, LIMITED CONTRAST WAS SEEN ON CTA. REPORTEDLY, THE POWER-LINE INFILTRATED. 100CC OF OMNI350 CONTRAST WAS INJECTED BUT AN UNKNOWN AMOUNT INFILTRATED AS SOME WAS SEEN ON CTA AND SOME LEAKED AROUND THE POWER-LINE CATHETER. PATIENT REQUIRED ADDITIONAL PROCEDURE TO REPLACE THE POWER-LINE CATHETER. REPORTEDLY THERE WAS NO HARM TO THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7248894 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC® Catheters 1174108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall222 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.