VASCU-PICC® MD17012601 (UDI 00884908142167)Recalls & reported problems

Medical Components, Inc. · 2.6F X 50CM DUAL LUMEN VASCU-PICC® BASIC SET · Class 2 · Implant

All models of VASCU-PICC (22)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00884908142167), received between Jan 27, 2026 and Sep 24, 2026 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Leak/Splash” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 2 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Leak/Splash4
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Bruise/Contusion1
  • Extravasation1
  • Pain1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjurySep 24, 2026Leak/Splash

    PICC dressing noted to have drainage so primary RN asked for assistance changing dressing. Once old, soiled dressing was taken down, leaking noted to be coming from actual catheter and not from insertion site. MD notified and PICC removed. PICC team attempted to get a new PICC line but was unable to see a vein that she felt comfortable using. PIV placed instead. Brusing noted around the insertion site. Once PICC removed, further inspection confirmed that there was a hole in actual catheter originating from the white lumen (lumen that had sedation and pressors infusing).

    Patient problems: Bruise/Contusion

    MAUDE report 50884329 ↗
  • InjuryJul 31, 2026Leak/Splash

    This event involves a patient who was admitted to "[redacted]" Pediatric Intensive Care Unit (PICU) on "[redacted]" from an outside hospital for surgical management. On "[redacted]"-the day of admission, the patient underwent surgery for an open external incision and drainage of the retropharyngeal and mediastinal abscess via the left neck. On "[redacted]"-post-op day 1, the patient underwent a bedside procedure to insert a peripherally inserted central catheter (PICC) in the right upper extremity for antibiotic therapy without complication.On "[redacted]"-post-op day 7, the patient demonstrated wincing when the white port of the PICC line was flushed as per routine. Initially a 10 cubic centimeter (cc) syringe was used to flush the port but was met with resistance. A second attempt was made to flush the port with a 3cc syringe that was filled with heparin prior to flushing. The patient continued to wince, and leaking was noted at the insertion site. An Intravenous Team (IV) nurse was consulted to evaluate the site. Assessment of the PICC also indicated that the red port was not flushing. A decision was made to discontinue use of the line and to remove the PICC. On "[redacted]"-pos

    Patient problems: Pain

    MAUDE report 50096990 ↗
  • InjuryJul 31, 2026Leak/Splash

    This event involves a patient who was admitted to "[redacted]" Pediatric Intensive Care Unit (PICU) on "[redacted]" from an outside hospital for monitoring and management. On "[redacted]"-hospitalization day #45, the 2.6 Fr picc line was found cracked at the hub when the PICC RN came to assess and administered a tissue plasma activator (TPA), which is a thrombolytic agent, to the line. The TPA was administered to both lumens but after the dwell both lumens were still very sluggish with no blood return. The dressing was removed to further investigate and was found to be wet underneath. The line was then flushed with the dressing off and leaking was visible from catheter. On "[redacted]"-hospitalization day #47 a new PICC was placed by IV RN on "[redacted]"-that day at 1123 at the bedside over a guidewire at the same site as the previous PICC and midline. PICC breakage a result of user error, not device failure although there were still concerns regarding the product by the team.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50096989 ↗
  • MalfunctionFeb 27, 2026Fracture

    PICC LINE FRACTURE WHICH IS NON-REPAIRABLE. WILL NEED TO BE REPLACED, EXCHANGED UNDER CARDIAC ANEESTHESIA SEDATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24471158 ↗
  • MalfunctionJan 27, 2026Leak/Splash

    AT 1600 RN RETURNS PATIENT TO BED FROM MOMS' ARMS AFTER DRAWING BLOOD FROM PICC LINE AND CSF FROM EVD. MOM NOTICES A WET SPOT ON HER SHIRT LEADING TO THE DISCOVERY OF A NEWLY INFILTRATED LUE PICC. THIS LINE WAS PLACED (B)(6). FAULTY LINE REMOVED FROM PT. NEW PICC PLACED BY PICC TEAM SUCCESSFULLY AND CONFIRMED BY XRAY.

    Patient problems: Extravasation

    MAUDE report 24187815 ↗

Other Catheter, intravascular, therapeutic, long-term greater than 30 days devices

All Catheter, intravascular, therapeutic, long-term greater than 30 days devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page