Visao™ 3334800TRecalls & reported problems
Medtronic Xomed, Inc. · DRILL 3334800T VISAO IGS 80K HANDPIECE · Class 2
All models of ViSAO (16)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 12
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 00885074107349), received between Feb 27, 2017 and Jan 25, 2024 — classified as 12 malfunctions.
The most frequently reported specific device problem is “Overheating of Device” (10 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Overheating of Device10
- Vibration2
- Connection Problem1
- Degraded1
- Fluid/Blood Leak1
- Noise, Audible1
Patient problems
- No Consequences Or Impact To Patient7
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 25, 2024Overheating of Device; Overheating of Device
IT WAS REPORTED INTRA INTRA-OP THE VISAO DRILL HANDPIECE WAS OVERHEATING. THERE WAS NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18579423 ↗MalfunctionJun 5, 2023Overheating of Device; Overheating of Device
IT WAS REPORTED THAT THE VISAO DRILL HANDPIECE DEVELOPED HEAT. THERE WAS NO KNOWN PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17058951 ↗MalfunctionDec 7, 2021Vibration; Vibration
A HEALTHCARE PROFESSIONAL (HCP) REPORTED THAT THE DEVICE IS WOBBLING DURING USE. ON FOLLOW-UP, IT WAS MENTIONED THAT THE DEVICE WAS VIBRATING WHILE USING ON THE PATIENT, DURING A TYMPANOPLASTY PROCEDURE. THERE WAS NO DELAY IN THE PROCEDURE AND NO BACKUP DEVICE WAS USED. THERE WAS NO PATIENT OR STAFF IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12951497 ↗MalfunctionAug 5, 2021Degraded; Overheating of Device; Noise, Audible; Degraded; Overheating of Device; Noise, Audible
A HEALTH CARE PROFESSIONAL (HCP) REPORTED THAT THE HANDPIECE OVERHEATED DURING USE. ON FOLLOW UP, IT WAS REPORTED THAT IT TOOK OVER ONE MINUTE BEFORE OVERHEATING OCCURRED. A BACK UP DEVICE WAS USED TO FINISH THE PROCEDURE WITH NO DELAY. IT WAS ALSO REPORTED THAT THERE IS NO IMPACT ON NEITHER THE PATIENT NOR THE STAFF.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12281926 ↗MalfunctionJun 11, 2021Fluid/Blood Leak; Overheating of Device; Fluid/Blood Leak; Overheating of Device
A HEALTH CARE PROVIDER REPORTED THAT THE HANDPIECE WAS OVERHEATING AND THE OIL WAS LEAKING DURING TYMPANOPLASTY. THERE WAS NO PATIENT OR STAFF IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11983035 ↗MalfunctionJun 1, 2020Vibration; Connection Problem; Vibration; Connection Problem
A HEALTHCARE PROFESSIONAL (HCP) REPORTED THAT THE BUR CANNOT BE INSERTED AND THAT THE BUR SHAKES WHEN ROTATING. THERE WAS NO PATIENT IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10106909 ↗MalfunctionDec 21, 2018Overheating of Device; Overheating of Device
A HEALTH CARE PROVIDER (HCP) REPORTED VIA A MANUFACTURER REPRESENTATIVE THAT THE TIP OF THE HANDPIECE OVERHEATED AFTER STARTING TO WORK. THERE WAS NO IMPACT SUCH AS BURN INJURIES TO THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8191787 ↗MalfunctionApr 27, 2018Overheating of Device; Overheating of Device
THE CUSTOMER REPORTED THAT THE DEVICE OVERHEATED. THERE WAS NO PATIENT IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7468626 ↗MalfunctionJan 5, 2018Overheating of Device; Overheating of Device
THE PHYSICIAN REPORTED THAT DURING A TYMPANOPLASTY, "WHEN THE FOOT SWITCH WAS STEPPED ON, THE DRILL ABNORMALLY OSCILLATED. THE HIGH-SPEED DRILL DID NOT OVERHEAT BUT HEATED [GOT WARM]. THE DRILL WAS NOT TOO HOT TO BE HELD BY HAND." THE PROCEDURE WAS COMPLETED WITH THE REPORTED PRODUCT. THERE WAS NO PATIENT IMPACT OR INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7167413 ↗MalfunctionNov 2, 2017Overheating of Device; Overheating of Device
THE CUSTOMER REPORTED THE DEVICE OVERHEATED AFTER A FEW MINUTES OF USE DURING A TYMPANOPLASTY. THE PRODUCT ANALYSIS CONFIRMS THE REPORTED EVENT OF OVERHEATING. THERE WAS NO DELAY TO THE PROCEDURE AND NO INJURIES REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6997676 ↗MalfunctionJun 2, 2017Overheating of Device; Overheating of Device
IT WAS REPORTED THAT THE HANDPIECE OVERHEATED. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6608320 ↗MalfunctionFeb 27, 2017Overheating of Device; Overheating of Device
IT WAS REPORTED THAT DURING A TYMPANOPLASTY SURGERY THE HANDPIECE OVERHEATED. THE PROCEDURE WAS COMPLETED WITH ANOTHER HANDPIECE. THERE WAS NO PATIENT IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6360930 ↗
Other DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE devices
- RemB 6400034000Stryker Corporation · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE1,618 reports
- NA XMAXAnspach Effort, The · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE1,225 reports
- NA EG1ASynthes GmbH · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE859 reports
- NA CRANI-ASynthes GmbH · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE1 recall772 reports
- NA 5450400000Stryker Corporation · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE775 reports
- NA 05.001.010Synthes GmbH · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE770 reports
- RemB 6400015000Stryker Corporation · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE603 reports
- NA QD11Synthes GmbH · DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE580 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page