TRIGEN 71691152Recalls & reported problems
Smith & Nephew, Inc. · SURESHOT HUMERAL DRILL GUIDE PROBE · Class 2
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00885556195284), received between Jul 24, 2018 and Jul 1, 2025 — classified as 2 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Application Program Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Application Program Problem1
- Connection Problem1
- Failure to Read Input Signal1
- Imprecision1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Information1
- No Known Impact Or Consequence To Patient1
- Perforation1
- Rupture1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 1, 2025Failure to Read Input Signal; Failure to Read Input Signal
IT WAS REPORTED THAT DURING THE OSTEOSYNTHESIS PROCEDURE, THE SURESHOT HUMERAL DRILL GUIDE PROBE AND THE DONUT WERE CONNECTED AND THE EQUIPMENT RECOGNIZED THEM, EACH STEP WAS PERFORMED AND WHEN IT WAS LOOKED AT WITH THE DONUT, IT NEVER SHOWED ANYTHING AND THERE WAS NO SIGNAL. THERE WAS A SIGNIFICANT DELAY AND THE PROCEDURE WAS FINISHED BY MANUALLY DRILLING THE HOLES. PATIENT WAS NOT HARMED BY THIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22371849 ↗InjuryAug 17, 2022Imprecision; Imprecision
IT WAS REPORTED THAT, DURING AND INTERNAL FIXATION SURGERY, THE SURESHOT HUMERAL DRILL GUIDE PROBE DID NOT CORRECTLY SHOW THE POINT FOR DISTAL BLOCKING OF THE HUMERAL ROD. SURGERY WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, WITH A CHANGE IN SURGICAL TECHNIQUE. PATIENT WAS NOT HARMED AS CONSEQUENCE OF THIS PROBLEM.
Patient problems: No Clinical Signs, Symptoms or Conditions; Perforation; Rupture
MAUDE report 15242434 ↗InjuryApr 5, 2021Connection Problem; Connection Problem
IT WAS REPORTED THAT DURING SURGERY A HO LOAN KIT WAS USED AND SEVERAL INCONVENIENT WERE NOTICED. THE SURESHOT HUMERAL DRILL GUIDE PROBE FAILED. THE PROXIMAL JIG WAS FAULTY CAUSING ALL OF THE PROXIMAL SCREWS TO MISS THE NAIL. ALL SCREWS ENDED UP BEING DONE BY HAND MAKING PERFECT CIRCLES WITH BOTH DISTAL SCREWS AND PROXIMAL SCREWS. IT WAS REPORTED A SIGNIFICANT THE CASE ENDED UP DELAYED FOR OVER 2 HOURS. THE PROCEDURE WAS COMPLETED WITH THE SAME DEVICE AND NO INJURIES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11616789 ↗MalfunctionDec 10, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING SURGERY, WHILE DRILLING THE DISTAL SCREW USING A SURESHOT, IT WAS FOUND THE HOLE WAS OUT OF ALIGNMENT. THEY BELIEVE GUIDE PROBE WAS SET AT "20" BUT IT ACTUALLY WASN'T. IT WAS LOOSED. EVEN WHEN THEY TRIED TO SET "20" AGAIN, IT DID NOT WORK. DELAY FORM, (0-30) MINUTES REPORTED. BACKUP DEVICE AVAILABLE. NO INJURY OR IMPACT TO PATIENT REPORTED.
Patient problems: No Information
MAUDE report 9443678 ↗MalfunctionJul 24, 2018Application Program Problem; Application Program Problem
IT WAS REPORTED THAT A NEW HUMERAL SURESHOT GUIDE WAS USED IN THE MIDDLE OF THE PROCEDURE, AND WHEN IT WAS CONNECTED TO THE MONITOR, IT DID NOT RECOGNIZE THE GUIDE; WE REALIZED THAT THE GUIDE WAS DAMAGED AND SPECIALIST HAD TO PERFORM THE NAIL DISTAL BLOCKS WITH FREEHAND AND THE HELP OF AN INTENSIFIER
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7713186 ↗
Other Orthopedic stereotaxic instrument devices
- REAL INTELLIGENCE ROB10024Smith & Nephew, Inc. · Orthopedic stereotaxic instrument1 recall924 reports
- NA 209063Mako Surgical Corp. · Orthopedic stereotaxic instrument2 recalls602 reports
- RESTORIS, RIO 212760Mako Surgical Corp. · Orthopedic stereotaxic instrument605 reports
- REAL INTELLIGENCE ROB10013Smith & Nephew, Inc. · Orthopedic stereotaxic instrument1 recall528 reports
- VELYS 4515-70-105Depuy (Ireland) · Orthopedic stereotaxic instrument578 reports
- VELYS 4515-70-106Depuy (Ireland) · Orthopedic stereotaxic instrument564 reports
- NA 209999Mako Surgical Corp. · Orthopedic stereotaxic instrument522 reports
- Mazor X System TPL0059-06Mazor Robotics Ltd · Orthopedic Stereotaxic Instrument2 recalls2 deaths392 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.