Skip to content

ZUK 00584202508Recalls & reported problems

Smith & Nephew, Inc. · Articular Surface Size 5 8mm · Class 2 · Implant

All models of ZUK (46)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00885556620212), received between Dec 22, 2020 and Feb 9, 2021 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

3 other recalls cover devices cleared under the same FDA submission (K033363); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break1
  • Manufacturing, Packaging or Shipping Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 9, 2021Break; Break

    IT WAS REPORTED THAT, DURING SURGERY, THE ARTICULAR SURFACE SIZE 5 9MM INSERT SNAPPED IN HALF. SURGEON LEFT IN PLACE THE INSERT UNTIL THE CEMENT CURED AND THEN REMOVED THE 2 PIECES. IT IS UNKNOWN HOW WAS THE PROCEDURE CONCLUDED. NO PIECES WERE LEFT INSIDE THE PATIENT. NO DELAY OCCURRED DUE TO THIS EVENT AND PATIENT WAS NOT HARMED BEYOND THE DESCRIBED EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11305578 ↗
  • MalfunctionDec 22, 2020Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem

    IT WAS REPORTED THAT WHEN THE REPLENISHMENT ARRIVED IT WAS NOTICED THAT THE PACKAGING WAS INCORRECT. NO PATIENT INVOLVED IN THE CASE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11057710 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K033363. One submission often covers many models, so check the product and lot details in each record.

  • Z-1054-2018 · Nov 29, 2017 · Terminated
    ZUK PRC FEM SZB RMED/LLAT ZUK PRC FEM SZC LMED/RLAT ZUK PRC FEM SZC RMED/LLAT NGU PRC FEM SZD LMED/RLAT ZUK PRC FEM SZD RMED/LLAT ZUK PRC FEM SZE LMED/RLAT ZUK PRC FEM SZF RMED/LLA
  • Z-0836-2016 · Jan 11, 2016 · Terminated
    ZIMMER UNI HIGH FLEX PRECOAT FEM prosthesis, knee, femorotibial, non-constrained, cemented, metal/polymer various sizes These devices are indicated for patients with: - Painful an
  • Z-0076-2014 · Aug 30, 2013 · Terminated
    Zimmer Unicompartmental Knee Femoral Component. Indicated for patients with painful and/or disabling knee joint.

Other PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER devices

All PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page