JOURNEY 74026168Recalls & reported problems
Smith & Nephew, Inc. · JOURNEY II UK XLPE TIBIA INSERT MEDIAL SIZE 5-6 8MM · Class 2 · Implant
All models of JOURNEY (566)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00885556677131), received between Jan 8, 2024 and Sep 25, 2025 — classified as 3 injuries.
The most frequently reported specific device problem is “Degraded” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K190085, K230653, K242711); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Degraded1
- Dent in Material1
- Fracture1
Patient problems
- Pain2
- Inadequate Osseointegration1
- Insufficient Information1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjurySep 25, 2025Degraded; Fracture; Degraded; Fracture
IT WAS REPORTED THAT, AFTER A UKA SURGERY, HAD BEEN PERFORMED ON (B)(6) 2024, THE POLY INSERT PRESENTED AN ABNORMAL WEAR. THE PATIENT FELT PAIN IN HER KNEE OVER A LONG PERIOD OF TIME. THERE WAS NOT ONE EVENT THAT CAUSED IT. THIS ADVERSE EVENT WAS ADDRESSED BY REVISION SURGERY ON (B)(6) 2025, IN WHICH THE JOURNEY II UK TIB INSRT MED SZ 5-6 8MM WAS EXCHANGED. THE PATIENT IS STILL IN THE RECOVERY PHASE OF THE CONVERSION SURGERY, HOWEVER, HAS BEEN RELIEVED OF MUCH OF THE PAIN THEY WERE EXPERIENCING FOLLOWING THE ORIGINAL PARTIAL KNEE REPLACEMENT.
Patient problems: Pain
MAUDE report 23151742 ↗InjuryApr 11, 2025Dent in Material; Dent in Material
IT WAS REPORTED THAT AFTER A TKA THAT TOOK PLACE ON (B)(6) 2023, A REVISION SURGERY TOOK PLACE ON (B)(6) 2025 DUE TO PAIN. AN UNKN JOURNEY II UNI KNEE IMPL AND IT WAS NOTICED THAT IT HAD A BIG DIVOT WHEN RETRIEVED. LATERAL COMPARTMENT WEAR WAS PROVIDED AS A POSSIBLE CAUSE. CURRENT PATIENT STATUS IS UNKNOWN.
Patient problems: Inadequate Osseointegration; Pain
MAUDE report 21827625 ↗InjuryJan 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON THE LITERATURE REVIEW "EARLY PERFORMANCE AND EFFICACY OF AN UPDATED UNICONDYLAR KNEE ARTHROPLASTY DESIGN: A REVIEW OF 73 CASES", IT WAS REPORTED THAT, AFTER UNDERGOING PRIMARY LEFT UKA ON (B)(6) 2019 DUE TO MEDIAL COMPARTMENT OSTEOARTHRITIS, ONE (1) PATIENT EXPERIENCED AN UNSPECIFIED COMPLICATION THAT WAS TREATED WITH A POLY EXCHANGE, ALONG WITH IRRIGATION AND DEBRIDEMENT, ON (B)(6) 2020.
Patient problems: Insufficient Information
MAUDE report 18463558 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K190085, K230653, K242711. One submission often covers many models, so check the product and lot details in each record.
- Z-2621-2023 · Aug 31, 2023 · Open, Classifiedsmith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint
- Z-1393-2023 · Mar 27, 2023 · Open, ClassifiedJOURNEY II UNI XLPE TIBIA INSERT MEDIAL SZ 7-8 8MM
- Z-2132-2020 · Jan 28, 2020 · TerminatedJOURNEY II UNI RESECTION PREP TRIAL, LEFT MEDIAL/ RIGHT LATERAL - Product Usage: The JOURNEY II Uni Resection Prep Trial is a reusable surgical instrument used during range of moti
- Z-2133-2020 · Jan 28, 2020 · TerminatedJOURNEY II UNI RESECTION PREP TRIAL, RIGHT MEDIAL/ LEFT LATERAL - Product Usage: The JOURNEY II Uni Resection Prep Trial is a reusable surgical instrument used during range of moti
Other PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.