CORI ROB10100Recalls & reported problems

Smith & Nephew, Inc. · CORI KNEE TENSIONER · Class 2

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00885556809600), received between Apr 23, 2024 and Mar 14, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Connection Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Connection Problem2
  • Communication or Transmission Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 14, 2026Communication or Transmission Problem

    IT WAS REPORTED THAT DURING A TKA, AFTER THE CORI KNEE TENSIONER HAD PASSED THE CALIBRATION, IT TIMED OUT DURING GAP STRESSING MULTIPLE TIMES. THIS CONTINUED EVEN AFTER CARTRIDGE RELATED TROUBLESHOOTING. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, CHANGING TO A MANUAL PROCEDURE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24600279 ↗
  • MalfunctionMay 7, 2024Connection Problem; Connection Problem

    IT WAS REPORTED THAT DURING CORI ASSISTED TKA SURGERY, THE CORI KNEE TENSIONER FAILED TO RECORD DATA WHEN TENSIONING THE JOINT. AT THE START OF THE CASE WHEN SETTING UP THE TENSIONER, THE TENSIONER CABLE WAS CONNECTED TO THE CORI, HOWEVER THE RE-USABLE COMPONENT HAD NOT BEEN CONNECTED TO THE CARTRIDGE BY THE NURSE YET. AFTER THE NURSE CONNECTED THE CARTRIDGE TO THE TENSIONER, A RECOLLECT ERROR CAME UP WHEN TRYING TO SET UP THE TENSIONER. THE TENSIONER WAS THEN DISCONNECTED FROM THE CORI UNIT AND FROM THE RE-USABLE COMPONENT AND RE-CONNECTED TO COLLECT THE STEP UP AGAIN, ANOTHER RE-CONNECT ERROR CAME UP. THE TENSIONER WAS UNPLUGGED AND REPLUGGED AGAIN AND ANOTHER ATTEMPT WAS MADE, THIS TIME THE SETUP COLLECTED AS NORMAL. HOWEVER, WHEN IT CAME TO USE THE TENSIONER IN THE JOINT, DR. PARKER REPORTED THE HE WAS SQUEEZING THE TENSIONER HOWEVER NOTHING WAS BEING COLLECTED ON THE SCREEN. THE DEVICE WAS UNPLUGGED AND REPLUGGED, THIS DID NOT SOLVE THE ISSUE. SURGERY WAS RESUMED AFTER A NON-SIGNIFICANT DELAY BY MANUAL PROCEDURE. NO INJURIES TO THE PATIENT WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19259449 ↗
  • MalfunctionApr 23, 2024Connection Problem; Connection Problem

    IT WAS REPORTED THAT DURING CORI ASSISTED TKA SURGERY, THE CORI KNEE TENSIONER KEPT DISCONNECTING. FOR 2 SECONDS IT WOULD ACT AS THOUGHT, THE PIECE WAS CONNECTED PROPERLY TO THE SYSTEM AND THEN WOULD DISCONNECT. THE TECH DISCONNECTED AND RECONNECTED THE REUSABLE AND DISPOSABLE PIECES BUT THIS DID NOT WORK. TECH ALSO TRIED SWITCHING USB PORTS BUT WAS UNSUCCESSFUL AS WELL. FINALLY, THE GAP ASSESSMENT WAS PERFORMED WITH MANUALLY AND THE SURGERY WAS COMPLETED WITH CORI AFTER A NON-SIGNIFICANT DELAY. NO INJURIES TO THE PATIENT WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19164806 ↗