NA 52856BRecalls & reported problems

Smith & Nephew, Inc. · Cup Impactor - Offset · Class 2

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00885556909393), received between May 7, 2024 and Jan 15, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 2 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component3
  • Break2
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 15, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A THA, WHILE THE PATIENT WAS UNDER ANESTHESIA, THE BOTTOM PLATE OF A CUP IMPACTOR - OFFSET POPPED OFF, LETTING THE SPRINGS AND PEGS COME OUT AS WELL. ALL PIECES RETAINED AND NOT MISSING. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY, USING THE SAME DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24079278 ↗
  • MalfunctionNov 18, 2025Break; Break

    IT WAS REPORTED THAT, DURING A CORI ASSISTED THA SURGERY, THE LOCKING MECHANISM OF A CUP IMPACTOR - OFFSET BROKE. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY, USING AN EQUIVALENT S+N BACK-UP. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23586448 ↗
  • MalfunctionNov 18, 2025Break; Break

    IT WAS REPORTED THAT, DURING A REAL INTELLIGENCE CORI ASSISTED THA SURGERY, THE LOCKING MECHANISM OF A CUP IMPACTOR - OFFSET BROKE AND WILL NOT LOCK ON THE IMPLANT. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY, USING AN EQUIVALENT S+N BACK-UP. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23586292 ↗
  • MalfunctionFeb 4, 2025Fracture; Detachment of Device or Device Component; Fracture; Detachment of Device or Device Component

    IT WAS REPORTED THAT, DURING A REAL INTELLIGENCE CORI ASSISTED THA SURGERY, WHILE IMPACTING, IT WAS NOTICED THAT A SILVER PLATE CAME OFF. AFTER FURTHER INVESTIGATION, IT WAS FOUND THAT IT CAME FROM ONE (1) BL OFFSET CUP IMPACTOR UNIVERSAL. IT WAS THE SMALL PLATE THAT IS UNDERNEATH THE IMPACTOR. A SPRING, AND WHAT APPEARED TO BE A NUT, WERE ALSO FOUND TO BE DETACHED FROM THE IMPACTOR. NO BROKEN PIECES FELL INTO OR WERE LEFT IN PATIENT. THE PROCEDURE WAS RESUMED WITHOUT DELAY CAUTIOUSLY USING THE SAME DEVICE, AND NO INJURIES WERE REPORTED AS A RESULT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21307031 ↗
  • MalfunctionMay 7, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING CORI ASSISTED THA SURGERY, AFTER IMPACTING THE CUP AND REMOVING THE BL OFFSET CUP IMPACTOR UNIVERSAL, THE LATCH ON THE FLAT SURFACE FELL OFF ALONG WITH THE SCREW AND SPRING. TECH WAS UNABLE TO PUT IT BACK TOGETHER. THIS OCCURRED AFTER THE CUP HAD BEEN PLACED AND WASN¿T NEEDED ANYMORE. THERE WERE NO PIECES THAT ENDED UP IN THE PATIENT AS A RESULT OF THIS BREAK. SURGERY WAS RESUMED WITHOUT ANY DELAY. NO INJURIES TO THE PATIENT WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions