ICU Medical CL-13-5Recalls & reported problems

Icu Medical, Inc. · 30" (76 cm) 20 Drop Admin Set w/Integrated ChemoLock™ Port Drip Chamber, ChemoLock™; 5 Units · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887709097452), received between Feb 13, 2026 and Feb 13, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

60 other recalls cover devices cleared under the same FDA submission (K131549); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Fluid/Blood Leak1
  • Particulates1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 13, 2026Fluid/Blood Leak; Particulates; Detachment of Device or Device Component

    AN EVENT INVOLVED A A CHEMOLOCK BAG SPIKE WITH ADDITIVE PORT, 5 UNITS WHERE THE CUSTOMER REPORTED THAT THE PRODUCT HAD RANDOM SHOWING OF WHAT LOOKS LIKE UV GLUE IN TUBING, AND DETACHMENT OF THE PORT ON THE 13 WHICH LED TO A LEAK OF CYCLOPHOSPHAMIDE THERE WAS PATIENT INVOLVEMENT AND NO HARM/ADVERSE EVENT REPORTED. THIS OCCURRED 2 TIMES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24335350 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K131549. One submission often covers many models, so check the product and lot details in each record.

  • Z-3159-2026 · May 12, 2026 · Open, Classified
    Oncology sets with drip chambers
  • Z-3161-2026 · May 12, 2026 · Open, Classified
    IV Sets with drip chambers
  • Z-2210-2026 · Mar 24, 2026 · Open, Classified
    Oncology Kit w/60" (152 cm) Appx 2.2 ml, Smallbore Ext Set w/ChemoLock Port, Clamp, Anti-Siphon Valve, Spiros; ChemoLock; Syringe Transfer Set w/MicroClave, ChemoLock Port, REF: CL
  • Z-0351-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical 21" Ext Set w/ChemoLock Port, Clamp, Graduated Connector REF: CL3360
  • Z-0345-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical ChemoLock Vented Vial Spike, 13mm REF: CL-72
  • Z-0349-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical ChemoLock 13mm Closed Vial Spike REF: CL-82
  • Z-0348-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical ChemoLock Closed Vial Spike w/Skirt, 5 Units REF: CL-80S-5
  • Z-0344-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical ChemoLock Vented Vial Spike, 20mm REF: CL-70S
  • Z-0362-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical Oncology Kit w/2 ChemoLock", 13mm Closed Vial Spike w/ChemoLock" Port, ChemoLock" Bag Spike, Ext Set w/ChemoLock" Port, Clamp, Graduated Adapter REF: CL4188
  • Z-0331-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical Clave Bag Spike w/ChemoLock Port REF: CL2150
  • Z-0363-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical ChemosafeLock Bag Spike REF: KL-BS001U3
  • Z-0352-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical Graduated Connector w/ChemoLock Port REF: CL3900
  • Z-0365-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical ChemosafeLock Vial Adapter REFs: KL-VA001U3 KL-VA002U3 KL-VA131U3 KL-VA201U3 KL-VA202U3 KL-VA321U3
  • Z-0329-2026 · Sep 8, 2025 · Open, Classified
    ICU Medical Chemo Lock Universal Vented Vial Spike REF: CL-70-10
  • Z-0328-2026 · Sep 8, 2025 · Open, Classified
    ChemoLock Bag Spike, 01 units REF: CL-10-10

…and 45 more.

Other Closed antineoplastic and hazardous drug reconstitution and transfer system devices

All Closed antineoplastic and hazardous drug reconstitution and transfer system devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page