ICU Medical 42800-23Recalls & reported problems
Icu Medical, Inc. · Transpac™IT Monitoring Kit Neonatal, 12", 3 Stopcocks, 30ml Flush (For Use with Infusion Pump) · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00887709097964), received between Nov 14, 2024 and Nov 21, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Deformation Due to Compressive Stress” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K052828); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Deformation Due to Compressive Stress2
- Inaccurate Information2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 21, 2024Deformation Due to Compressive Stress; Inaccurate Information; Deformation Due to Compressive Stress; Inaccurate Information
THE EVENT INVOLVED A TRANSPAC¿ IT MONITORING KIT NEONATAL, 12", 3 STOPCOCKS, 30ML FLUSH (FOR USE WITH INFUSION PUMP). THE REPORTER STATED THAT THE PRODUCT WAS INVOLVED IN A PATIENT SAFETY REPORT IN THE FACILITY. THE ISSUE WAS THAT THE IV TUBING WAS BENT CAUSING AN ALARM FOR HIGH PRESSURE. THE WAVEFORM WAS DAMPENED OR WOULD READ AS DISCONNECTED AND WOULD CAUSE ALARMS TO GO OFF. THERE WAS PATIENT INVOLVEMENT AND THERE WAS DELAY IN THERAPY; HOWEVER, THERE WAS NO HUMAN HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20752410 ↗MalfunctionNov 14, 2024Deformation Due to Compressive Stress; Inaccurate Information; Deformation Due to Compressive Stress; Inaccurate Information
THE EVENT INVOLVED A TRANSPAC¿ IT MONITORING KIT NEONATAL, 12", 3 STOPCOCKS, 30ML FLUSH (FOR USE WITH INFUSION PUMP) WHERE THE REPORTER STATED THAT THE IV TUBING IS BENT CAUSING AN ALARM FOR HIGH PRESSURE. IT WAS STATED THAT WHEN THEY TRIED TO ZERO THE LINE, THE WAVEFORM WAS DAMPENED OR WOULD READ AS DISCONNECTED. IT WOULD CAUSE ALARMS TO GO OFF. AFTER TROUBLESHOOTING WITH A FLEX NURSE, THEY NOTICED THAT THE LINE ENTERING THE TRANSDUCER WAS COMPRESSED DOWN. THEY STRAIGHTENED THE IV TUBING CONNECTING TO THE TRANSDUCER AND GOT AN ACCURATE READING, HOWEVER AS SOON AS RELEASED THE TUBING AGAIN WAS FACED WITH THE SAME ALARMS AND DAMPENED WAVE FORM. THERE WAS PATIENT INVOLVEMENT, AND NO HUMAN HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20684408 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K052828. One submission often covers many models, so check the product and lot details in each record.
- Z-1071-2019 · Nov 27, 2018 · TerminatedICU Medical, Transpac IV Monitoring Kit With Safeset Reservoir and Blood Sampling Port, 60" Tubing, Disposable Transducer, 3 ml Squeeze Flush, Macrodrip (Pole Mount), REF: 42640-06
Other Transducer, blood-pressure, extravascular devices
- Acumen IQ AIQS85Edwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall7 reports
- Acumen IQ AIQS8R5Edwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall1 report
- ACUMEN IQ SENSOR AIQS6AZ5Edwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall1 report
- Acumen IQ AIQS8Edwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall1 report
- Acumen IQ AIQS65Edwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall0 reports
- ACUMEN IQ SENSOR AIQS6AZEdwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall0 reports
- Acumen IQ AIQS6R5Edwards Lifesciences LLC · Transducer, Blood-Pressure, Extravascular1 recall0 reports
- NAMIC 70036160Medline Industries, Inc. · Transducer, blood-pressure, extravascular1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page