Skip to content

Arthrex® AR-11794LRecalls & reported problems

Arthrex, Inc. · SUTURE CUTTER, OPEN ENDED, LEFT NOTCH · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00888867003590), received between Sep 26, 2022 and Dec 9, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Failure to Cut1
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Insufficient Information1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 9, 2025Fracture; Fracture

    ON 11/21/2025, IT WAS REPORTED BY AN ARTHREX SUBSIDIARY EMPLOYEE VIA (B)(4) THAT AN AR-11794L SUTURE CUTTER FRACTURED DURING USE. THIS WAS DISCOVERED DURING INTRA-ARTICULAR MANIPULATION WITH NO PATIENT HARM. THE ENTIRE ITEM WAS REMOVED WITHOUT LEAVING ANY FRAGMENTS INSIDE THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23757837 ↗
  • MalfunctionJun 11, 2024Break; Break

    ON 05/15/2024 IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT AN AR-11794L SUTURE CUTTER BROKE. THIS OCCURRED DURING USE IN A CASE WITH NO PATIENT EFFECT. A NEW SUTURE CUTTER WAS USED TO COMPLETE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19509081 ↗
  • MalfunctionApr 18, 2024Break; Break

    IT WAS REPORTED THAT INTERNAL LINKAGE THAT CONNECTS THE HANDLE TO THE JAW SEEMS TO BE BROKEN/DISCONNECTED.

    Patient problems: Insufficient Information

    MAUDE report 19133438 ↗
  • MalfunctionSep 26, 2022Break; Failure to Cut

    ON 09/07/2022, IT WAS REPORTED BY AN ARTHREX EMPLOYEE VIA SEMS THAT AN AR-11794L SUTURE CUTTER HAD AN ISSUE. DURING A ROTATOR CUFF REPAIR SURGERY ON (B)(6) 2022, THE SUTURE CUTTER WAS BROKEN SUDDENLY, IT COULD NOT CUT ANYMORE. THE PIECE BROKE OFF INSIDE THE PATIENT, THE FRAGMENT WAS RETRIEVED FROM THE PATIENT AND THERE WAS NO HARM TO THE PATIENT. THE SURGEON USED ANOTHER NEW PRODUCT WITH THE SAME TYPE AND LOT NUMBER TO COMPLETE THE PROCEDURE SUCCESSFULLY, NO SECOND OPERATION WAS NEEDED. THIS WAS DISCOVERED DURING USE WITH NO IMPACT TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15484223 ↗

Other INSTRUMENT, MANUAL, SURGICAL, GENERAL USE devices

All INSTRUMENT, MANUAL, SURGICAL, GENERAL USE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page