Arthrex® AR-1204AS-115Recalls & reported problems
Arthrex, Inc. · FLIPCUTTER II, SHORT 11.5MM · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867004313), received between Feb 27, 2019 and Apr 23, 2025 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Deformation Due to Compressive Stress1
- Failure to Eject1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 23, 2025Break; Break
ON 04/10/2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA PHONE THAT AN AR-120AS-115 FLIPCUTTERS HINGE BROKE. THIS OCCURRED DURING AN ACL KNEE ARTHROSCOPY ON (B)(6) 2025 WHEN THE HINGE BROKE. ALL FRAGMENTS WERE RETRIEVED FROM THE PATIENT. THE PATIENT HAD A VERY HARD BONE QUALITY. THIS CAUSED A 15-MINUTE DELAY THAT DID NOT REQUIRE ADDITIONAL ANESTHESIA. THEY USED ANOTHER TO COMPLETE THE CASE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21892362 ↗InjuryFeb 27, 2019Deformation Due to Compressive Stress; Failure to Eject
IT WAS REPORTED BY A SALES REP WHO WAS PRESENT THAT THE AR-1204AS-115, 11.5MM FLIPCUTTER, WAS USED IN A KNEE ARTHROSCOPY PROCEDURE ON (B)(6) 2019. PER THE SALES REP, THE SURGEON PERFORMED THE FLIPCUTTER TECHNIQUE CORRECTLY. HE PRE-DRILLED IN THE FEMUR WITH A 3.5MM DRILL UNTIL THE INSIDE PORTION OF THE MEDIAL CONDYLE WAS REACHED. ONCE THE 3.5MM PREDRILL WAS COMPLETED, THE 11.5MM FLIPCUTTER WAS INTRODUCED THROUGH THE PREDRILLED HOLE INTO THE JOINT. PER THE SALES REP, THE SURGEON CORRECTLY DEPLOYED THE FLIPCUTTER COMPLETELY, AND THEN HE PERFORMED THE RETROGRADE DRILLING ACTION. THE SOCKET WAS CREATED WITHOUT ISSUE. HOWEVER, THE ISSUE CAME WHEN IT WAS TIME TO STRAIGHTEN OUT THE FLIP CUTTER AND PULL IT OUT OF THE 3.5MM STEP DRILL SLEEVE. THE FLIP CUTTER WAS STRAIGHTENED; HOWEVER, THE FLIPCUTTER COULD NOT BE REMOVED FROM THE JOINT. THE DOCTOR USED A PITUITARY AND PROBE TO DO HIS BEST TO STRAIGHTEN OUT THE FLIPCUTTER AS MUCH AS POSSIBLE, HOWEVER THE FLIPCUTTER WOULD NOT STRAIGHTEN OUT COMPLETELY, MAKING IT IMPOSSIBLE TO PULL IT OUT OF THE 3.5MM STEP DRILL SLEEVE. THE SURGEON ENDED UP HAVING TO PULL THE STEP DRILL SLEEVE OUT OF THE CORTEX OF THE LATERAL EPICONDYLE IN ORDER TO REMOVE THE FL
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8375672 ↗
Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices
- NA 511.701Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT2,164 reports
- SmartLife 7126-120-000Stryker Corporation · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT1,065 reports
- NA 05.001.224Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT987 reports
- NA 05.001.206Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT632 reports
- NA 532.021Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT521 reports
- NA 2570-04-501Depuy (Ireland) · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT500 reports
- NA 532.110Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT433 reports
- NA 05.001.223Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT397 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page