Arthrex® AR-12250Recalls & reported problems
Arthrex, Inc. · SUTURE CUTTER, 4.2 MM, STRAIGHT · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00888867005655), received between Mar 1, 2021 and May 22, 2024 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break3
- Defective Device1
- Detachment of Device or Device Component1
- Failure to Cut1
Patient problems
- Insufficient Information4
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 22, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
ON 04/25/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS-06548841 THAT AN AR-12250 SUTURE CUTTERS PIN IN THE JAW OF THE CUTTER WAS STICKING OUT AND WHEN THE DEVICE WAS INSPECTED FURTHER AND ATTEMPTED TO PUSH IT BACK IN, THE PIN FELL OUT. THE JAWS OF THE CUTTER WERE NO LONGER FUNCTIONAL. THIS OCCURRED DURING A SHOULDER SCOPE. NO ADDITIONAL INFORMATION WAS PROVIDED, AND ADDITIONAL INFORMATION HAS BEEN ASKED.
Patient problems: Insufficient Information
MAUDE report 19378255 ↗MalfunctionMay 4, 2023Break; Break
ON (B)(6) 2023, IT WAS REPORTED BY A FACILITY REPRESENTATIVE VIA SEMS THAT AN AR-12250 SUTURE CUTTER BROKE. THIS OCCURRED DURING A CASE, AFTER ATTEMPTING TO CUT THE SUTURE, A PIECE BROKE OFF THAT DISCONNECTS FROM THE TOP CUTTING PORTION FROM THE ACTIVATING HANDLE. THERE WAS NO PATIENT EFFECT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16869671 ↗MalfunctionSep 6, 2022Break
ON 08/19/2022, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT A AR-12250 SUTURE CUTTER IS BROKEN. THIS WAS DISCOVERED DURING AN UNKNOWN CASE, WITH NO PATIENT EFFECT REPORTED. ADDITIONAL INFORMATION REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15362442 ↗MalfunctionJun 20, 2022Break
IT WAS REPORTED ON (B)(6) 2021 BY A FACILITY REPRESENTATIVE VIA SEMS THAT AN AR-12250 SUTURE CUTTER IS BROKEN NON-SPECIFICALLY. THIS WAS DISCOVERED DURING A CASE WITH NO PATIENT HARM.
Patient problems: Insufficient Information
MAUDE report 14743862 ↗MalfunctionAug 3, 2021Defective Device
IT WAS REPORTED THAT DURING A SHOULDER ARTHROSCOPIC PROCEDURE, THE TIP OF THE AR-12250 WOULD NOT WORK. THE CASE WAS COMPLETED BY USING A NEW AR-12250 WITHOUT FURTHER ISSUE. THIS IS NOW REPORTABLE. DURING RETURNED DEVICE EVALUATION, A REPORTABLE MALFUNCTION WAS DISCOVERED.
Patient problems: Insufficient Information
MAUDE report 12268662 ↗MalfunctionMar 1, 2021Failure to Cut
IT WAS REPORTED THAT THE SUTURE CUTTER IS NOT CUTTING. THIS IS NOW REPORTABLE. DURING RETURNED DEVICE EVALUATION, A REPORTABLE MALFUNCTION WAS DISCOVERED.
Patient problems: Insufficient Information
MAUDE report 11392550 ↗
Other INSTRUMENT, MANUAL, SURGICAL, GENERAL USE devices
- Arthrex® AR-13995NArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE430 reports
- Arthrex® AR-12990NArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE197 reports
- Arthrex® AR-13991NArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE128 reports
- Arthrex® AR-8981-08SArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall3 reports
- Arthrex® AR-8981-06SArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall1 report
- Centurion EB16Centurion Medical Products Corporation · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall0 reports
- Medline Industries, Inc. DYNJ901391DMedline Industries, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall0 reports
- HarmonyAIR LAS0042Steris Corporation · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page