Arthrex® AR-13975SRRecalls & reported problems

Arthrex, Inc. · FIBERWIRE GRASPER W/ SR HANDLE · Class 1

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00888867015838), received between Apr 21, 2017 and Nov 18, 2025 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Break” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break6
  • Detachment Of Device Component1
  • Device Or Device Fragments Location Unknown1
  • Entrapment of Device1
  • Material Twisted/Bent1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Foreign Body In Patient2
  • Insufficient Information1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 18, 2025Break; Break

    ON 11/03/2025, A SALES REPRESENTATIVE REPORTED VIA (B)(4) THAT THE AR-13975SR FIBERWIRE GRASPER TIP BROKE OFF. THIS WAS DISCOVERED DURING A CASE WITH NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23584324 ↗
  • MalfunctionNov 22, 2024Break; Break

    ON 10/30/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT AN AR-13975SR FIBERWIRE® GRASPER BROKE. THIS OCCURRED DURING A SHOULDER ARTHROSCOPY ON (B)(6) 2024. THE BOTTOM JAW BROKE OFF WHILE INSERTING THE INSTRUMENT INTO THE JOINT.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20758995 ↗
  • MalfunctionDec 27, 2022Material Twisted/Bent; Break; Material Twisted/Bent

    ON (B)(6) 2022, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT A AR-13975SR FIBERWIRE® GRASPER W/SR HANDLE IS BROKEN AT THE DISTAL END OF THE TIP. THIS OCCURRED DURING A CASE, NO PIECES WERE LEFT IN THE PATIENT, AND THE CASE WAS COMPLETED. THERE WAS NO PATIENT EFFECT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16051575 ↗
  • MalfunctionNov 16, 2021Break

    ON (B)(6) 2021, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT AN AR-13975SR FIBERWIRE GRASPER, DISTAL END BROKE. THIS WAS DISCOVERED DURING USE IN PROCEDURE ON (B)(6) 2021. ALL FRAGMENT WERE REMOVED FROM THE PATIENT.

    Patient problems: Foreign Body In Patient

    MAUDE report 12819165 ↗
  • MalfunctionMay 24, 2021Break

    IT WAS REPORTED THAT DURING A RCR/ BANKART PROCEDURE, THE AR-13975SR BROKE. THE FRAGMENT WAS REMOVED AND THE CASE WAS COMPLETED BY USING A NEW AR-13975SR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11872439 ↗
  • InjuryApr 21, 2017Break; Detachment Of Device Component; Entrapment of Device; Device Or Device Fragments Location Unknown

    IT WAS REPORTED THAT DURING A ROTATOR CUFF REPAIR PROCEDURE, THE SURGEON WAS USING THE FIBERWIRE GRASPER WITH SR HANDLE TO GRASP THE BICEPS TENDON. THE UPPER JAW OF THE GRASPER BROKE-OFF INTO THE PATIENT'S JOINT. THE SURGEON ATTEMPTED TO LOCATE THE JAW FRAGMENT WITH THE SCOPE HOWEVER, COULD NOT LOCATE IT. THE SURGEON THEN HAD AN X-RAY BROUGHT IN AND WAS ABLE TO CONFIRM THE LOCATION OF THE JAW FRAGMENT BUT WAS UNABLE TO RETRIEVE IT. A SECOND SURGERY IS UNDETERMINED AT THE MOMENT AND THE SURGEON WILL WATCH FOR ANY SYMPTOMS BEING CAUSED BY THE DEVICE FRAGMENT.

    Patient problems: Foreign Body In Patient

    MAUDE report 6511012 ↗

Other Accessories, arthroscopic devices

All Accessories, arthroscopic devices →