Skip to content

Arthrex® AR-15310WRecalls & reported problems

Arthrex, Inc. · PUNCH,MED 3.4 MM15°UP CRVD,220MM W/WB · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867018686), received between Feb 21, 2022 and Feb 21, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 21, 2022Break

    ON (B)(6) 2022 IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT AN AR-15310W PUNCH, BROKEN DURING A CASE, PATIENT WAS NOT AFFECTED. ADDITIONAL INFORMATION 02/09/2022: ON (B)(6) 2022 IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT WHEN THE SURGEON WAS USING THE AR-15310W PUNCH ON THE LABRUM, IT BROKE. THE INSTRUMENT BROKE IN THE PATIENT BUT IT LOOKS TO BE AN INTERNAL BREAKAGE OF THE WISH BONE AREA OF THE HANDLE. NOTHING WAS LEFT IN THE PATIENT. THIS WAS DISCOVERED DURING USE IN A LARGE CALCIFIED HIP LABRUM TEAR ON (B)(6) 2022. THE CASE WAS COMPLETED BY USING THE SHAVER AND BANANA BLADE TO FINISH THE RESECTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13569731 ↗

Other Accessories, arthroscopic devices

All Accessories, arthroscopic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page