Arthrex® AR-2254RRecalls & reported problems
Arthrex, Inc. · AC GUIDE, RIGHT · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867026247), received between Sep 18, 2019 and Jul 1, 2020 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 1, 2020Break
IT WAS REPORTED THAT THE HEAD OF THE DEVICE BROKE OFF DURING AN ACROMIO CLAVICULAR DISLOCATION SURGERY. THE BROKEN PIECE WAS RETRIEVED FROM THE PATIENT'S BODY. ACCORDING TO THE REPORTER, THE SURGICAL TECHNIQUE HAD TO BE CHANGED BUT NO DETAILS WERE GIVEN WHAT HAD TO BE CHANGED AND THE FOLLOWING WAS REPORTED: "UNUSABLE MATERIAL HAS TO BE REPLACED BY ANOTHER SYSTEM WHOSE SECONDARY ABLATION WILL BE NECESSARY". UPDATE 22-JUNE-2020: THE FOLLOWING INFORMATION HAS BEEN MADE AVAILABLE TODAY: IT WAS IMPOSSIBLE TO PUT ON THE ENDO-BUTTON, SO THE SURGEON PUT A PIN TO HOLD THE COLLARBONE IN PLACE IN FRONT OF THE SCAPULAR. THE SURGERY TOOK APPROX. 30 - 45 MIN LONGER THAN EXPECTED DUE TO THIS INCIDENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10217860 ↗InjurySep 18, 2019Break
IT WAS REPORTED THAT THE DEVICE BROKE. THE EXTREMITY DISSOCIATED FROM THE REST OF THE VIEWFINDER WHEN IT WAS PUT IN PLACE FOR ARTHROSCOPIC ACROMIOCLAVICULAR DYSJUNCTION INTERVENTION. BROKEN PIECE WAS RETRIEVED FROM PATIENT. NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY WAS REPORTED. THE SURGERY WAS FINISHED SUCCESSFULLY. UPDATE 28-AUG-2019: SURGEON HAD TO CHANGE SURGICAL TECHNIQUE. THE PLANNED TECHNIQUE WAS ARTHROSCOPIC ACROMIO CLAVICULAR DYSJUNCTION. BECAUSE OF THE INCIDENT, THE SURGEON HAD TO CHANGE HIS INTERVENTION TO AN OPEN PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9081026 ↗
Other INSTRUMENT, MANUAL, SURGICAL, GENERAL USE devices
- Arthrex® AR-13995NArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE430 reports
- Arthrex® AR-12990NArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE197 reports
- Arthrex® AR-13991NArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE128 reports
- Arthrex® AR-8981-08SArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall3 reports
- Arthrex® AR-8981-06SArthrex, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall1 report
- Centurion EB16Centurion Medical Products Corporation · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall0 reports
- Medline Industries, Inc. DYNJ901391DMedline Industries, Inc. · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall0 reports
- HarmonyAIR LAS0042Steris Corporation · INSTRUMENT, MANUAL, SURGICAL, GENERAL USE1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page