Arthrex® AR-602-28Recalls & reported problems
Arthrex, Inc. · iBALANCE PFJ BLADE KIT, SIZE 3 · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867038257), received between Dec 6, 2024 and Dec 6, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 6, 2024Patient Device Interaction Problem; Patient Device Interaction Problem
ON 11/11/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT AN AR-602-28 IBALANCE¿ PFJ BLADE KIT FRACTURED THE LEFT FEMORAL CONDYLE WHILE PREPPING THE FEMUR WITH A BLADE KIT DURING A CASE. THE CASE WAS COMPLETED SUCCESSFULLY, AND NO FURTHER INFORMATION WAS PROVIDED. NO PIECES BROKE INSIDE THE PATIENT REPORTED. THIS WAS DISCOVERED DURING A PFJ PROCEDURE ON (B)(6) 2024. ADDITIONAL INFORMATION WAS RECEIVED ON 11/14/2024: THE REP STATED THAT THE CONDYLE FRACTURED WHILE THE SURGEON IMPACTED THE PROXIMAL BLADE AND USED THE STANDARD SURGICAL TECHNIQUE INDICATED. AFTER THE FRACTURE, A NON-ARTHREX HEADLESS SCREW WAS USED TO STABILIZE THE FRACTURE, AND AN ARTHREX IBALANCE PFJ SYSTEM COMPLETED THE CASE WHILE USING THE STANDARD TECHNIQUE. THERE WAS A 10-MINUTE DELAY WHILE THEY WAITED FOR THE NON-ARTHREX PRODUCT TO BE RECEIVED. NO X-RAYS ARE AVAILABLE OF THE PATIENT. NO MEDICAL INTERVENTION OR HOSPITALIZATION WAS NEEDED FOR THE PATIENT, AND NO ADDITIONAL SURGERY WAS REQUIRED.
Patient problems: Bone Fracture(s)
MAUDE report 20865443 ↗
Other BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL devices
- NA 511.801Synthes GmbH · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL223 reports
- Formula 0375544000Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL98 reports
- NA 0277096325Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL95 reports
- NA 310.25Synthes GmbH · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL91 reports
- Arthrex® AR-8400TDArthrex, Inc. · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL86 reports
- NA 0277096275Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL72 reports
- Arthrex® AR-7300DSArthrex, Inc. · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL70 reports
- NA 0277096277Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL69 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.