Skip to content

Arthrex® AR-8954-05Recalls & reported problems

Arthrex, Inc. · ELEVATOR, SAYRE, 9MM X 6.5" LONG · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867055261), received between Mar 6, 2025 and Mar 6, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 6, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    ON 02/19/2025, A FACILITY REPRESENTATIVE REPORTED VIA (B)(4) THAT AN AR-8880-01 RASP AND BLUNT ELEVATOR SMALL, AR-8880-02 RASP AND BLUNT ELEVATOR MEDIUM, AR-8880-03 COMBI-ELEVATOR STRAIGHT AND CURVED ENDS, AND AN AR-8954-05 ELEVATOR SAYRE 9MM X6.5'' HANDLES ARE THIN AND REQUIRE A TIGHT GRIP THAT FATIGUES THE HAND. THE SHARP EDGE IS TOO SHARP, AND IN SOME BONE, IT GOES INTO THE BONE - WHICH IS NOT THE IDEAL ASPECT. IT SHOULD BE MORE LIKE A FREER TIP VS A SHARP EDGE. THIS OCCURRED DURING A CASE. THERE WAS NO ADDITIONAL INFORMATION PROVIDED, AND ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21535530 ↗

Other INSTRUMENT, MANUAL, SURGICAL, GENERAL USE devices

All INSTRUMENT, MANUAL, SURGICAL, GENERAL USE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page