Arthrex® AR-600SAGMISRecalls & reported problems

Arthrex, Inc. · SAW ATTACHMENT-SAG MINIMAL INVASIVE CUTS · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00888867111103), received between Mar 5, 2024 and Feb 11, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 2 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component3
  • Break2
  • Device Dislodged or Dislocated1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 11, 2025Break; Break

    ON 01/28/2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT TWO (QTY.2) AR-600SAGMIS SAGITTAL SAW ATTACHMENTS ARE FALLING APART AND UNABLE TO CONNECT BLADE ATTACHMENTS. THEY OCCURRED DURING USE IN A CASE. NO HARM WAS DONE TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21353743 ↗
  • MalfunctionFeb 11, 2025Break; Break

    ON 01/28/2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT TWO (QTY.2) AR-600SAGMIS SAGITTAL SAW ATTACHMENTS ARE FALLING APART AND UNABLE TO CONNECT BLADE ATTACHMENTS. THEY OCCURRED DURING USE IN A CASE. NO HARM WAS DONE TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21353717 ↗
  • MalfunctionJan 7, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    ON 12/11/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT AN AR-600SAGMIS SAGITTAL SAW ATTACHMENT FELL APART DURING A CASE. NO HARM WAS DONE TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21095277 ↗
  • MalfunctionOct 14, 2024Detachment of Device or Device Component; Device Dislodged or Dislocated; Detachment of Device or Device Component; Device Dislodged or Dislocated

    ON 09/24/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS-06671072 THAT AN AR-600SAGMIS SAGITTAL SAW ATTACHMENT CAME APART DURING A CASE. THIS WAS DISCOVERED DURING A PROCEDURE, WITH NO REPORTED PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20439274 ↗
  • MalfunctionMay 16, 2024Use of Device Problem; Use of Device Problem

    IT WAS REPORTED ON 10/20/2021 BY A FACILITY REPRESENTATIVE VIA (B)(4) THAT AN AR-600SAGMIS SAW ATTACHMENT DOES NOT GRAB THE BLADE AND THAT COMPLICATES THE CUT. THIS WAS DISCOVERED DURING A CASE WITH NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19331306 ↗
  • MalfunctionMar 5, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE SAW ATTACHMENT BECOMES LOOSE WHILE SAWING. DUE TO THAT ISSUE, THE SAW BLADE FALLS OUT OF THE ATTACHMENT. THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY REPORTED. THIS WAS NOTICED BEFORE THE SURGERY. NO FURTHER INFORMATION RECEIVED. UPDATE DW: 16-FEB-2024: FURTHER INFORMATION WERE PROVIDED THAT APPARENTLY THE EVENT OCCURRED DURING USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18835638 ↗

Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices

All INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page