Arthrex® AR-3610ND-2Recalls & reported problems
Arthrex, Inc. · Flexible Drill, FiberTak, 1.8mm · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867358683), received between Dec 27, 2023 and Jun 10, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 10, 2024Break; Break
ON 12/1/2022, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3636 KNOTLESS FIBERTAK INSERTER BROKE OFF DURING INSERTION. ALL FRAGMENTS WERE RETRIEVED, AND CASE WAS COMPLETED WITH ANOTHER ARTHREX ANCHOR. THIS WAS DISCOVERED DURING A PROCEDURE ON (B)(6) 2022. AN ADDITIONAL 20 MINUTES WERE ADDED TO THE CASE DUE TO DEVICE BREAKING. ADDITIONAL INFORMATION RECEIVED ON 12/1/2022: A TOTAL OF (2) AR-3636 KNOTLESS FIBERTAK INSERTERS BROKE INSIDE THE PATIENT AND ALL FRAGMENTS WERE RETRIEVED. DUE TO THE CASE BEING DELAYED FOR 20 MINUTES, ADDITIONAL ANESTHESIA WAS ADMINISTERED TO THE PATIENT. ALSO, SURGEON HAD DIFFICULTY INSERTING THE ANCHOR THROUGH THE DRILL SLEEVE OF AN AR-3610ND-2 FLEXIBLE 1.8MM DRILL, AN AR-3610CTC CURVED FIBERTAK SPEAR, AND (2) AR-3610CTC-2 TIGHT CURVED FIBERTAK SPEAR. THIS WAS DISCOVERED DURING A LABRAL REPAIR PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19499288 ↗MalfunctionDec 27, 2023Break; Break
IT WAS REPORTED THAT DURING A LABRUM STABILISATION SURGERY WITH FIBERTAK THE TIP OF THE DRILL BROKE OFF OUTSIDE THE PATIENT. THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY. THE SURGERY WAS FINISHED SUCCESSFULLY WITH A NEW DEVICE WITH THE SAME PART NUMBER. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18402816 ↗
Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices
- NA 511.701Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT2,164 reports
- SmartLife 7126-120-000Stryker Corporation · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT1,065 reports
- NA 05.001.224Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT987 reports
- NA 05.001.206Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT632 reports
- NA 532.021Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT521 reports
- NA 2570-04-501Depuy (Ireland) · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT500 reports
- NA 532.110Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT433 reports
- NA 05.001.223Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT397 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page