Arthrex® AR-9094-085LRecalls & reported problems

Arthrex, Inc. · Telescoping lag screw, LT, 10.5 x 85mm · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867409989), received between Feb 2, 2026 and Feb 2, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Positioning Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 2, 2026Positioning Failure

    ON 08-JAN-2026, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA PHONE THAT AN AR-9094-090L LEFT LAG SCREW, AN AR-S0100-381 GUIDE PIN, AN AR-S0457-000 ACTIVATION TOOL, AR-S0100-000 GUIDE PIN, AR-S0219-100 DRILL, AR-S0209-200 DRILL, AR-9094-11-2030 TROCHANTERIC NAIL, AND AN AR-9094-085L LAG SCREW WERE USED IN A CASE AND NEITHER SCREW WERE ABLE TO LOCK INTO THE NAIL AFTER IMPLANTATION. ALL IMPLANTS WERE FULLY EXPLANTED, AND THE SURGERY WAS COMPLETED USING A COMPETITOR PRODUCT NAIL. THIS OCCURRED DURING USE IN A CASE WITH NO PATIENT EFFECT. DELAY IN CASE 50 MINUTES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24234138 ↗

Other Rod, Fixation, Intramedullary And Accessories devices