Skip to content

Mityvac 10008Recalls & reported problems

Coopersurgical, Inc. · Mityvac Vacuum-Assist Delivery System Super M-Style® Mushroom Cup Vacuum-Assist Delivery System · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888937003055), received between Mar 23, 2023 and Mar 23, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Mechanical Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Mechanical Problem1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 23, 2023Mechanical Problem; Mechanical Problem

    DETAILS REPORTED ON INCOMING (B)(4).ARE AS FOLLOWS: "WHEN PULLING, DOCTOR HAD A FEELING THAT CUP IS ABOUT TO BREAK (SOUND, FEELING IN HAND WHEN PULLING). THEY CHANGED THE CUP TO THE SAME KIND OF CUP. THAT CUP WAS FINE. NEVERTHELESS DELIVERY ENDED UP TO EMERGENCY C-SECTION. CHANGING THE CUP TOOK TIME AND THAT WAY EFFECTED TO DECISION." "PATIENT (MOTHER) SUFFERED 2000 ML BLOOD LOSS AND HAD BLOOD TRANSFUSION (2 UNITS) ONE DAY AFTER DELIVERY. SHE HAS RECOVERED AND BEEN DISCHARGED FROM HOSPITAL. MIDWIFE DIDN'T TELL ME BABY'S STATUS."

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 16600576 ↗

FDA clearance and classification

Cleared through 510(k) K943938 on May 3, 1995 (decision: Substantially Equivalent). Submitted by Neward Enterprises, Inc. as “Mityvac Super M Style Vacum Extractor, Disposable”. The FDA review took 264 days. FDA record ↗

The FDA regulates product code HDB (extractor, vacuum, fetal) under 21 CFR 884.4340 as a Class II device. 21 CFR 884.4340 ↗

Common questions about the Mityvac 10008

Has the Mityvac 10008 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00888937003055), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Mityvac 10008?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 23, 2023. That report lists device problem “Mechanical Problem” (1); patient problem “Hemorrhage/Blood Loss/Bleeding” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Mityvac 10008?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Mityvac 10008 FDA approved?

It was cleared through 510(k) K943938 on May 3, 1995. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Mityvac 10008, and is it still sold?

The FDA's device database lists Coopersurgical, Inc. as the company responsible for it (brand Mityvac, model 10008). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Extractor, Vacuum, Fetal devices

All Extractor, Vacuum, Fetal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page