Skip to content

NexGen® 5880-40-26Recalls & reported problems

Zimmer, Inc. · Class 2 · Implant

All models of NexGen (198)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024199354), received between Mar 24, 2022 and Mar 24, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

4 other recalls cover devices cleared under the same FDA submission (K013385, K173057); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 24, 2022Fracture; Fracture

    IT WAS REPORTED THAT AN IMPLANT WAS RECEIVED FRACTURED. TEAM MEMBER NOTICED THAT IT SOUNDED AS IF A PART WAS LOOSE WITHIN THE PACKAGE. A SIMILAR ITEM NUMBER IN THE SAME KIT SEEMED TO HAVE THE SAME ISSUE AND, UPON INSPECTION, IT WAS DISCOVERED THAT THE CAVITY WAS FRACTURED, AND THE HINGE POST EXTENSION WAS ROAMING AROUND LOOSE IN THE BOX. IT IS SUSPECTED THAT THIS ITEM HAS THE SAME ISSUE. THERE IS NO ADDITIONAL INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13893209 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K013385, K173057. One submission often covers many models, so check the product and lot details in each record.

  • Z-2092-2023 · May 19, 2023 · Terminated
    NexGen Precoat Stemmed Tibial Plate Size 5
  • Z-0321-2020 · Oct 10, 2019 · Terminated
    Various Knee Systems for knee joint arthroplasty, knee prosthesis, Item Nos. 00522000100 00522000200 00522000300 00522000400 00522006304 00522006504 00522006600 00522006800
  • Z-1447-04 · Aug 3, 2004 · Terminated
    Zimmer brand NEXGEN Complete Knee Solution Rotating Hinge Knee Tibial Component, precoat, nonmodular, size 2, sterile, for cemented use only; Cat. No. 5880-02-02.
  • Z-1448-04 · Aug 3, 2004 · Terminated
    Zimmer brand NEXGEN Complete Knee Solution Rotating Hinge Knee Tibial Component, precoat, nonmodular, size 3, sterile, for cemented use only; Cat. No. 5880-03-02.

Other PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER devices

All PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER devices →

Sources and updates