NexGen® 5972-16-02Recalls & reported problems
Zimmer, Inc. · Class 2 · Implant
All models of NexGen (198)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024215078), received between May 26, 2023 and May 26, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Wrong Label” (1 report).
105 other recalls cover devices cleared under the same FDA submission (K031061, K173057, K911572, K933785); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Wrong Label1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 26, 2023Wrong Label; Wrong Label
IT WAS REPORTED THAT DURING AN INITIAL TOTAL KNEE ARTHROPLASTY, THE SIZE OF THE FEMORAL COMPONENT DID NOT CORRESPOND TO THE SIZE ON THE PACKAGING. THE SURGEON PREPARED THE KNEE FOR A CERTAIN SIZE AND THE IMPLANT THAT WAS OPENED WAS ONE SIZE TOO LARGE, DESPITE INDICATING IT WAS THE CORRECT SIZE ON THE PACKAGE. NO PATIENT IMPACT OR ADVERSE EVENTS HAVE BEEN REPORTED AS A RESULT OF THE MALFUNCTION AND THE SURGERY WAS COMPLETED WITH A DIFFERENT IMPLANT OF THE CORRECT SIZE. DUE DILIGENCE IS IN PROCESS FOR THIS EVENT; TO DATE NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17011045 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K031061, K173057, K911572, K933785. One submission often covers many models, so check the product and lot details in each record.
- Z-1608-2024 · Mar 28, 2024 · Open, ClassifiedNexGen CR-Flex Femoral Component, Size E and Size E Minus (E-). Component of the NexGen CR-Flex Porous Femur System.
- Z-2092-2023 · May 19, 2023 · TerminatedNexGen Precoat Stemmed Tibial Plate Size 5
- Z-0321-2020 · Oct 10, 2019 · TerminatedVarious Knee Systems for knee joint arthroplasty, knee prosthesis, Item Nos. 00522000100 00522000200 00522000300 00522000400 00522006304 00522006504 00522006600 00522006800
- Z-1038-2018 · Nov 29, 2017 · TerminatedLPS POROUS FEM IMPLANT SZ G-L LPS PRECOAT FEM IMPLANT SZ G-L This device is indicated for patients with severe knee pain and disability
- Z-1039-2018 · Nov 29, 2017 · TerminatedLPS PRECOAT SRF HDN FEM SZ D-L LPS PRECOAT SRF HDN FEM SZ D-R LPS PRECOAT SRF HDN FEM SZ E-L LPS POROUS SRF HDN FEM SZ D-LT LPS POROUS SRF HDN FEM SZ E-LT This device is indicated
- Z-1040-2018 · Nov 29, 2017 · TerminatedLPS PRECOAT FEM SIZE D-RT LPS PRECOAT FEM SIZE E-RT LPS POROUS FEM SIZE F-RT This device is indicated for patients with severe knee pain and disability
- Z-1041-2018 · Nov 29, 2017 · TerminatedCR PRECOAT FEM COMP SIZE BMR CR PRECOAT FEM COMP SIZE C/R CR PRECOAT FEM COMP SIZE D/R CR PRECOAT FEM COMP SIZE E/R CR PRECOAT FEM COMP SIZE F/R CR PRECOAT FEM COMP SIZE G/L CR PRE
- Z-1030-2018 · Nov 29, 2017 · TerminatedCR POR FEM HATCP SIZE E/L SIZE F/L Knee Prosthesis
- Z-1048-2018 · Nov 29, 2017 · TerminatedCR-FLEX POR FEM F-L CR-FLEX POR FEM F-R MINUS CR-FLEX POR FEM G-L This device is indicated for patients with severe knee pain and disability
- Z-1042-2018 · Nov 29, 2017 · TerminatedCR OPTION FEM COMP SIZE C/L CR OPTION FEM COMP SIZE C/R CR OPTION FEM COMP SIZE D/L CR OPTION FEM COMP SIZE D/R CR OPTION FEM COMP SIZE E/L CR OPTION FEM COMP SIZE E/R CR OPTION FE
- Z-2115-2017 · Apr 28, 2017 · TerminatedNexGen Offset Stem Extension, sizes 14mm and 17mm For use in total arthroplasty.
- Z-1147-2016 · Jan 11, 2016 · TerminatedProduct 49 consists of all product under product code: JWH and same usage: Item no: 597206529 NEXGEN ALL-POLY PATELLA, 597206532 NEXGEN ALL-POLY PATELLA, 597206535 NEXGEN ALL-POL
- Z-1159-2016 · Jan 11, 2016 · TerminatedProduct 61 consists of all product under product code: JWH and same usage: Item no: 598003712 STD PRECOAT TIBIA PLATE S for use in total knee arthroplasty
- Z-1151-2016 · Jan 11, 2016 · TerminatedProduct 53 consists of all product under: product code: JWH and same usage: Item no: 597002501 NEXGEN PRECOAT PEG TIB PL 597002502 NEXGEN PRECOAT PEG TIB PL 597003501 NEXGEN PR
- Z-0835-2016 · Jan 11, 2016 · TerminatedNexGen Knee CR Option Fem NexGen Knee CR Porous Fem NexGen Knee CR Precoat Fem NexGen Knee LPS Porous Fem NexGen Knee LPS Precoat Fem prosthesis, knee, patellofemorotibial, semi-co
…and 90 more.
Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices
- ATTUNE 1512-14-050Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER106 reports
- ATTUNE 1504-40-205Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall53 reports
- ATTUNE 1504-40-105Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall46 reports
- ATTUNE 1547-06-001Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall37 reports
- ATTUNE 1513-12-060Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER72 reports
- Triathlon 5521-B-300Howmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- Triathlon 5531-G-709-EHowmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- ATTUNE 1512-16-080Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page