Skip to content

NexGen® 5990-35-01Recalls & reported problems

Zimmer, Inc. · Class 2 · Implant

All models of NexGen (198)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00889024224070), received between Oct 29, 2021 and Oct 29, 2021 — classified as 2 injuries.

The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (2 reports).

23 other recalls cover devices cleared under the same FDA submission (K173057, K946150, K960279); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Loosening of Implant Not Related to Bone-Ingrowth2

Patient problems

  • Failure of Implant2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 29, 2021Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Failure of Implant

    MAUDE report 12720177 ↗
  • InjuryOct 29, 2021Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Failure of Implant

    MAUDE report 12720107 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K173057, K946150, K960279. One submission often covers many models, so check the product and lot details in each record.

  • Z-1039-2025 · Jan 6, 2025 · Open, Classified
    NexGen LCCK Legacy Articular Surface with Locking Screw - Striped Yellow/E,F - Height 10 mm, Item Number 00-5994-032-10
  • Z-1038-2025 · Jan 6, 2025 · Open, Classified
    NexGen LCCK Legacy Articular Surface with Locking Screw - Striped Purple/C,D - Height 14 mm, Item Number 00-5994-022-14
  • Z-2092-2023 · May 19, 2023 · Terminated
    NexGen Precoat Stemmed Tibial Plate Size 5
  • Z-0321-2020 · Oct 10, 2019 · Terminated
    Various Knee Systems for knee joint arthroplasty, knee prosthesis, Item Nos. 00522000100 00522000200 00522000300 00522000400 00522006304 00522006504 00522006600 00522006800
  • Z-1035-2018 · Nov 29, 2017 · Terminated
    LPS OPTION FEMORAL C-L LPS OPTION FEMORAL C-R LPS OPTION FEMORAL D-L LPS OPTION FEMORAL D-R LPS OPTION FEMORAL E-L LPS OPTION FEMORAL E-R LPS OPTION FEMORAL F-L LPS OPTION FEMORAL
  • Z-1034-2018 · Nov 29, 2017 · Terminated
    LPS FEM IMPLANT SZ H-R This device is indicated for patients with severe knee pain and disability
  • Z-1036-2018 · Nov 29, 2017 · Terminated
    LPS FEM COMP SZ B-L LPS FEM COMP SZ B-R LPS FEM COMP SZ C-L LPS FEM COMP SZ C-R LPS FEM COMP SZ D-L LPS FEM COMP SZ D-R LPS FEM COMP SZ E-L LPS FEM COMP SZ E-R LPS FEM COMP SZ F-L
  • Z-1040-2018 · Nov 29, 2017 · Terminated
    LPS PRECOAT FEM SIZE D-RT LPS PRECOAT FEM SIZE E-RT LPS POROUS FEM SIZE F-RT This device is indicated for patients with severe knee pain and disability
  • Z-1037-2018 · Nov 29, 2017 · Terminated
    LCCK FEM IMPLANT SZ C-L LCCK FEM IMPLANT SZ C-R LCCK FEM IMPLANT SZ D-R LCCK FEM IMPLANT SZ E-L LCCK FEM IMPLANT SZ E-R LCCK FEM IMPLANT SZ F-L LCCK FEM IMPLANT SZ F-R This device
  • Z-0834-2016 · Jan 11, 2016 · Terminated
    NexGen Knee LPS Porous FEM NexGen Knee LPS Option FEM NexGen Knee Lock FEM prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer/metal/polymer various sizes Pr
  • Z-1146-2016 · Jan 11, 2016 · Terminated
    Product 48 consists of all product under product code: JWH and same usage: Item no: 597206526 NEXGEN ALL-POLY PATELLA, for use in total knee arthroplasty
  • Z-1575-2015 · Apr 2, 2015 · Terminated
    NexGen Augment; 5mm Distal Femoral Augment;Part number 00-5990-036-10. Intended to be used in total knee arthroplasty when there is insufficient bone in the distal femur.
  • Z-1023-2014 · Oct 11, 2013 · Terminated
    MODULAR CUP NEUTRAL LINER MODULAR CUP 10 DEGREE LIN MODULAR CUP 20 DEGREE LIN MODULAR CUP 7MM OFFSET LI
  • Z-0531-2011 · Sep 15, 2010 · Terminated
    Zimmer, NexGen Complete Knee Solution LPS Femoral Component, Size F Right, sterile, REF 00-5996-016-02.
  • Z-0530-2011 · Sep 15, 2010 · Terminated
    Zimmer, NexGen Complete Knee Solution LPS Femoral Component, Size F Left, sterile, REF 00-5996-016-01.

…and 8 more.

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page