Zimmer® Natural Nail® System 47-2485-090-10Recalls & reported problems
Zimmer GmbH · ZNN CMN LAG SCREW 10.5X90 · Class 2 · Implant
All models of Zimmer Natural Nail System (57)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 10
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00889024298439), received between Dec 19, 2018 and Mar 20, 2025 — classified as 10 injuries.
The most frequently reported specific device problem is “Fracture” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture7
- Insufficient Device Problem Information2
- Appropriate Device Problem Term/Code Not Available1
- Break1
- Separation Problem1
Patient problems
- Failure of Implant3
- Bone Fracture(s)2
- No Code Available2
- Extraskeletal ossification1
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
- No Information1
- Pain1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
InjuryMar 20, 2025Fracture; Fracture
DILIGENCE IS COMPLETED AND NO FURTHER INFORMATION ON THE REPORTED EVENT HAS BEEN PROVIDED.
Patient problems: Foreign Body In Patient
MAUDE report 21653766 ↗InjuryMay 23, 2024Separation Problem; Separation Problem
IT WAS REPORTED THAT PATIENT HAD AN INITIAL OPEN REDUCTION INTERNAL FIXATION ON THE LEFT SIDE. SUBSEQUENTLY, APPROXIMATELY 8 MONTHS POST-IMPLANTATION, REVISION WAS NEEDED DUE TO EXIT OF THE CERVICAL SCREW FROM THE JOINT AND SINKING INTO THE ACETABULUM. DURING THE REVISION IT WAS NOTED THAT THE ACETABULAR ROOF WAS FRACTURED. ALL COMPONENTS WERE EXCHANGED WITH COMPETITOR PRODUCT. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.
Patient problems: Bone Fracture(s); Failure of Implant; Pain
MAUDE report 19383577 ↗InjuryMar 3, 2022Fracture; Fracture
IT WAS REPORTED THAT: AFTER 2 MONTHS OF IMPLANTATION THERE WAS A BREAK IN THE FITTING OF THE PROXIMAL FIXATION SCREW OF THE FEMORAL NECK TOGETHER WITH THE FEMORAL NAIL, WHICH RESULTED A REVISION.
Patient problems: Bone Fracture(s); Failure of Implant
MAUDE report 13658386 ↗InjuryFeb 3, 2022Fracture; Fracture
IT WAS REPORTED THAT: NAIL SNAPPED AT LAG SCREW JUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13440250 ↗InjuryJul 30, 2021Fracture; Insufficient Device Problem Information; Fracture; Insufficient Device Problem Information
DURING THE EXPLANTATION OF THE METAL NAILS IT WAS FOUND THAT THE PATIENT'S CALLUS WAS COVERED WITH THE SCREW TAIL CAP. THE INTERMEDULLARY NAIL COULD NOT BE REMOVED AND WAS LEFT INSIDE THE PATIENT. THE SURGEON USED THE STANDARD LAG SCREW REMOVAL TOOL, BUT THE TAIL WAS BROKEN OFF AND HE HAD TO GIVE UP. THE SURGERY BEGAN AT 9AM AND ENDED AT 2-3PM.
Patient problems: Extraskeletal ossification
MAUDE report 12252729 ↗InjuryJul 13, 2021Break; Fracture; Break; Fracture
NO EVENT UPDATE. INVESTIGATION RESULTS ARE NOW AVAILABLE.
Patient problems: Failure of Implant
MAUDE report 12157909 ↗InjuryDec 30, 2019Fracture; Fracture
InjuryJun 13, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
InjuryJun 11, 2019Fracture; Fracture
InjuryDec 19, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT TWO ZNN LAG SCREW GOT DAMAGED DURING THE SURGERY RESULTING IN 40 MINUTES DELAY OF SURGERY.
Patient problems: No Information
MAUDE report 8177932 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page