Skip to content

Kinectiv® 00-7848-013-01Recalls & reported problems

Zimmer, Inc. · Class 2 · Implant

All models of Kinectiv (21)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024509467), received between Jan 9, 2024 and Jan 9, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Material Erosion” (1 report).

1 other recall cover devices cleared under the same FDA submission (K071856, K182678); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Erosion1

Patient problems

  • Metal Related Pathology1
  • Pain1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 9, 2024Material Erosion; Material Erosion

    UPON REASSESSMENT OF THE REPORTED EVENT, IT WAS DETERMINED TO BE NOT REPORTABLE AS THIS PRODUCT DID NOT CAUSE OR CONTRIBUTE TO THE EVENT. THE INITIAL REPORT SHOULD BE VOIDED.

    Patient problems: Metal Related Pathology; Pain

    MAUDE report 18474769 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K071856, K182678. One submission often covers many models, so check the product and lot details in each record.

  • Z-1699-2015 · May 18, 2015 · Terminated
    M/L Taper with Kinectiv Technology. prosthesis, hip, semi-constrained (metal uncemented acetabular component) Product Usage: Usage: Total hip replacement for the following: sever

Other Prosthesis, hip, semi-constrained, metal/polymer, uncemented devices

All Prosthesis, hip, semi-constrained, metal/polymer, uncemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page