Globus Medical, Inc. · CREO® Threaded 6.5 x 45mm Polyaxial Screw · Class 2

All models of CREO (100)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00889095104158), received between Dec 7, 2020 and Mar 14, 2025 — classified as 2 injuries, 8 malfunctions.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 6 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520266
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information3
  • Use of Device Problem2
  • Appropriate Device Problem Term/Code Not Available1
  • Break1
  • Fracture1
  • Loss of or Failure to Bond1
  • Mechanical Problem1

Patient problems

  • Insufficient Information8
  • Complaint, Ill-Defined1
  • Spinal Column Injury1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 14, 2025Fracture; Fracture

    IT WAS REPORTED THAT A CREO THREADED SCREW WAS FOUND BROKEN POST OPERATIVELY. THIS EVENT OCCURRED IN JAPAN.

    Patient problems: Insufficient Information

    MAUDE report 21609552 ↗
  • MalfunctionMar 5, 2024Loss of or Failure to Bond; Loss of or Failure to Bond

    IT WAS REPORTED THAT A REVISION SURGERY WAS NEEDED DUE TO CREO THREADED 6.5X45MM POLYAXIAL SCREWS THAT WERE FOUND LOOSE POST OPERATIVELY. THIS EVENT OCCURRED IN JAPAN.

    Patient problems: Insufficient Information

    MAUDE report 18838035 ↗
  • MalfunctionMar 5, 2024Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT THERE WAS A REVISION TO REPLACE CREO THREADED SCREWS THAT WERE FOUND LOOSE POST OPERATIVELY WITH SUBSEQUENT SPACER MIGRATION. THIS EVENT OCCURRED IN JAPAN.

    Patient problems: Insufficient Information

    MAUDE report 18834180 ↗
  • MalfunctionMar 4, 2024Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT A REVISION SURGERY WAS REQUIRED DUE TO A LOOSENED SCREW WHICH SHOWED HALOING.

    Patient problems: Spinal Column Injury

    MAUDE report 18830965 ↗
  • InjuryMar 4, 2024Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT POST-OPERATIVE IMAGING SHOWED THAT THE LEFT L4 AND S1 PEDICLE SCREWS WERE NOT PLACED PROPERLY. REVISION SURGERY WAS PERFORMED TO REPOSITION.

    Patient problems: Insufficient Information

    MAUDE report 18827140 ↗
  • MalfunctionMar 2, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED A CREO ROD BECAME LOOSE TWENTY-THREE DAYS POST-OPERATIVELY.

    Patient problems: Insufficient Information

    MAUDE report 18823395 ↗
  • MalfunctionMar 2, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED A CREO SCREW HAD BEEN PLACED MEDIALLY AND THE PATIENT WAS EXPERIENCING PAIN POST-OPERATIVELY. ADDITIONALLY, CREO SCREWS HAD LOOSENED DUE TO POOR BONE QUALITY.

    Patient problems: Insufficient Information

    MAUDE report 18823381 ↗
  • MalfunctionFeb 29, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT A MAGINIFY-S SPACER WITH HA COATED SCREWS WERE PLACED ANTERIORLY. THE PATIENT WAS THEN FLIPPED TO PLACE THE CREO PEDICLE SCREWS POSTERIORLY AND WHILE INSERTING ONE SCREW, IT SUBSEQUENTLY PUSHED OUT ONE OF THE SCREWS SECURING THE SPACER.

    Patient problems: Insufficient Information

    MAUDE report 18810323 ↗
  • MalfunctionFeb 22, 2021Break

    IT WAS REPORTED BY A REPRESENTATIVE FROM BELGIUM THAT A REVISION SURGERY WAS DONE DUE TO A SCREW WHICH HAD BROKEN 6 WEEKS POST-OPERATIVELY WITH LOSS OF COMPRESSION AND PUSH BACK OF 1 OF THE SUSTAIN CAGES.

    Patient problems: Insufficient Information

    MAUDE report 11362285 ↗
  • InjuryDec 7, 2020Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED BY A REPRESENTATIVE FROM (B)(6) THAT A REVISION SURGERY WAS DONE TO REPLACE 2 OF 3 SCREWS WHICH HAD DEVIATED POST-OPERATIVELY CAUSING ADVERSE EFFECTS TO THE PATIENT.

    Patient problems: Complaint, Ill-Defined

    MAUDE report 10962609 ↗

Other Orthosis, spinal pedicle fixation, for degenerative disc disease devices

All Orthosis, spinal pedicle fixation, for degenerative disc disease devices →