SuperCable® Iso-Elastic™ Cerclage System 37-100-1010Recalls & reported problems
Kinamed, Inc. · 1.0mm Polymer Cable with Ti Clasp · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00898142001975), received between Feb 15, 2016 and Feb 15, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Off-Label Use” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Off-Label Use1
Patient problems
- Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 15, 2016Off-Label Use; Off-Label Use
ON (B)(6) 2015, A PEDIATRIC PLASTIC SURGEON IN JAPAN PERFORMED A PROCEDURE TO CORRECT A "PIGEON CHEST" DEFORMITY USING WHAT WAS DESCRIBED AS A TYPE OF NUSS TECHNIQUE. IN THIS PROCEDURE, THE SURGEON USED 1.0MM SUPERCABLE ISO-ELASTIC CERCLAGE IMPLANTS (PART NUMBER 37-100-1010) TO SECURE A BIOMET PECTUS BAR TO THE RIBS. THE ENDS OF EACH SUPERCABLE IMPLANT WERE THREADED THROUGH A SINGLE HOLE ON EITHER SIDE OF THE PECTUS BAR IMPLANT. ON (B)(6) 2015, THE SURGEON DETERMINED THAT THE CABLE OF ONE OF THE 1.0MM SUPERCABLE ISO-ELASTIC CERCLAGE IMPLANTS WAS SEVERED. THE SURGEON PERFORMED A REVISION SURGERY ON (B)(6) 2016 WHERE THE 1.0MM CABLE WAS EXPLANTED AND REPLACED WITH A 1.5MM SUPERCABLE ISO-ELASTIC CERCLAGE IMPLANT (PART NUMBER 35-100-1010). THE OUTCOME OF THE SURGERY WAS SUCCESSFUL AND THE PATIENT WAS DISCHARGED ON (B)(6) 2016.
Patient problems: Injury
MAUDE report 5436849 ↗
Other CERCLAGE, FIXATION devices
- ZipFix 03.501.080Synthes GmbH · CERCLAGE, FIXATION236 reports
- CONTROL 1739-28-000Depuy Orthopaedics, Inc. · CERCLAGE, FIXATION52 reports
- Dall-Miles 6704-0-110Howmedica Osteonics Corp. · CERCLAGE, FIXATION1 recall1 report
- Tritium® Sternal Cable Plate System 86-27-12-S12Pioneer Surgical Technology, Inc. · CERCLAGE, FIXATION1 recall0 reports
- Accord 71340007Smith & Nephew, Inc. · CERCLAGE, FIXATION47 reports
- ZipFix 08.501.001.01SSynthes GmbH · CERCLAGE, FIXATION39 reports
- NA 298.801.01SSynthes GmbH · CERCLAGE, FIXATION33 reports
- ZipFix 08.501.001.05SSynthes GmbH · CERCLAGE, FIXATION29 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page