Etest® MEROPENEMRecalls & reported problems
Biomerieux SA · Etest is a quantitative technique for determining susceptibility of clinically significant bacteria. It provides a gradient of 15 doubling dilutions for MIC determination. · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03573026546984), received between Sep 24, 2020 and Sep 24, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings2
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 24, 2020Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
A CUSTOMER FROM THE UNITED STATES NOTIFIED BIOMÉRIEUX OF DISCREPANT MEROPENEM SUSCEPTIBLE RESULTS WHEN TESTING KLEBSIELLA PNEUMONIA STRAINS ISOLATED FROM A PATIENT'S SAMPLE USING ETEST® METHOD (REF. 513848, LOT 1007583220). THE CUSTOMER STATED THEY INOCULATED THE SUSPENSION OF THE MICROORGANISM ISOLATED FROM THE PATIENT'S SAMPLE INTO BIOMÉRIEUX MHE AGAR AND APPLIED THE MEROPENEM ETEST STRIP LOT 1007583220; AFTER INCUBATION THE CUSTOMER OBTAINED A MEROPENEM MIC VALUE OF 0.25 G/ML, CATEGORIZING THE STRAIN TO BE SUSCEPTIBLE TO THIS ANTIMICROBIAL AGENT. THE CUSTOMER MENTIONED THAT A SUSPENSION OF THE SAME MICROORGANISM ISOLATED FOR THE SAME PATIENT'S WAS TESTED FOR ANTIBIOTIC SUSCEPTIBILITY TEST USING VITEK® 2 AST-GN79 TEST KIT (REF. 413436) AND A MIC >16 G/ML WAS OBTAINED THAT CATEGORIZED THE STRAIN TO BE RESISTANT TO MEROPENEM. THE CUSTOMER ALSO PERFORMED CARBANP TEST FOR CARBAPENEMASE DETECTION AND A POSITIVE RESULT WAS OBTAINED; THIS IS NOT CONSISTENT WITH THE SUSCEPTIBLE RESULT TO MEROPENEM. THERE IS NO INDICATION OR REPORT FROM THE LABORATORY THAT THE DISCREPANT RESULT LED TO ANY ADVERSE EVENT RELATED TO THE PATIENT'S STATE OF HEALTH.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10581120 ↗MalfunctionSep 24, 2020Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
A CUSTOMER FROM THE UNITED STATES NOTIFIED BIOMÉRIEUX OF DISCREPANT MEROPENEM SUSCEPTIBLE RESULTS WHEN TESTING KLEBSIELLA PNEUMONIA STRAINS ISOLATED FROM A PATIENT'S SAMPLE USING ETEST® METHOD (REF. 513848, LOT 1007735480). THE CUSTOMER STATED THEY HAD INOCULATED THE SUSPENSION OF THE MICROORGANISM ISOLATED FROM THE PATIENT'S SAMPLE INTO BIOMÉRIEUX MHE AGAR AND APPLIED THE MEROPENEM STRIP LOT 1007735480; AFTER INCUBATION THE CUSTOMER OBTAINED A MEROPENEM MIC VALUE OF 0.25 G/ML, CATEGORIZING THE STRAIN TO BE SUSCEPTIBLE TO THIS ANTIMICROBIAL AGENT. THE CUSTOMER INDICATED THAT THEY HAD ALSO PERFORMED CARBANP TEST FOR CARBAPENEMASE DETECTION AND A POSITIVE RESULT WAS OBTAINED; THIS IS NOT CONSISTENT WITH THE SUSCEPTIBLE RESULT TO MEROPENEM. THERE IS NO INDICATION OR REPORT FROM THE LABORATORY THAT THE DISCREPANT RESULT LED TO ANY ADVERSE EVENT RELATED TO THE PATIENT'S STATE OF HEALTH.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10581078 ↗
Other Manual Antimicrobial Susceptibility Test Systems devices
- ETEST® Imipenem/Relebactam (IPR)Biomerieux SA · Manual antimicrobial susceptibility test systems1 recall4 reports
- ETEST® Amikacin (AK)Biomerieux SA · Manual Antimicrobial Susceptibility Test Systems1 recall2 reports
- ETEST® Tobramycin (TM)Biomerieux SA · Manual Antimicrobial Susceptibility Test Systems1 recall1 report
- ETEST® Erythromycin (EM)Biomerieux SA · Manual Antimicrobial Susceptibility Test Systems1 recall0 reports
- ETEST® Rifampicin (RI)Biomerieux SA · Manual Antimicrobial Susceptibility Test Systems1 recall0 reports
- ETEST® Eravacycline (ERV)Biomerieux SA · Manual antimicrobial susceptibility test systems1 recall0 reports
- ETEST® Benzylpenicillin (PG)Biomerieux SA · Manual Antimicrobial Susceptibility Test Systems1 recall0 reports
- ETEST® Ampicillin (AM)Biomerieux SA · Manual Antimicrobial Susceptibility Test Systems1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page