ACUFEX 012020Recalls & reported problems
Smith & Nephew, Inc. · PUNCH BASKET SCOOP UPBITER 1.5MM · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010023469), received between Feb 13, 2020 and May 14, 2021 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Material Separation1
Patient problems
- Foreign Body In Patient1
- Laceration(s)1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 14, 2021Break; Break
IT WAS REPORTED THAT DURING AN ARTHROSCOPY FOR A KNEE MENISCUS, THE PUNCH BASKET BROKE OFF IN THE PATIENT'S JOINT (METAL PIECE OF 0.5CM X 1.5CM). AN X-RAY WAS PERFORMED TO LOCATE THE PIECE AND AN ADDITIONAL INCISION WAS MADE ON THE PATIENT TO REMOVE IT RESULTING IN A SURGICAL DELAY OF 8 MINUTES. IT IS UNKNOWN IF A BACK-UP DEVICE WAS AVAILABLE. NO OTHER COMPLICATIONS WERE REPORTED. CURRENT PATIENT STATUS WAS REPORTED AS ¿GOOD¿.
Patient problems: Laceration(s); No Clinical Signs, Symptoms or Conditions
MAUDE report 11828574 ↗MalfunctionFeb 13, 2020Material Separation; Material Separation
IT WAS REPORTED THAT DURING A KNEE ARTHROSCOPY, THE PUNCH BASKET BROKE INSIDE THE PATIENT. THE BROKE PIECE REMAINED IN THE PATIENT'S KNEE ALTHOUGH THE OPERATOR STRUGGLED TO RESCUE IT. PATIENT RELEASED WITH THE BROKE PART OF THE INSTRUMENT IN THE KNEE. IT IS UNKNOWN IF THERE WAS A DELAY IN THE PROCEDURE. THE PROCEDURE WAS COMPLETED USING THE SAME DEVICE. NO PATIENT INJURIES WERE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: Foreign Body In Patient
MAUDE report 9706396 ↗
Other ACCESSORIES,ARTHROSCOPIC devices
- Arthrex® AR-12990Arthrex, Inc. · Accessories, arthroscopic409 reports
- NA 228302Medos International Sàrl · ACCESSORIES,ARTHROSCOPIC287 reports
- FIRSTPASS 72290128Smith & Nephew, Inc. · ACCESSORIES,ARTHROSCOPIC232 reports
- NA 251723Medos International Sàrl · ACCESSORIES,ARTHROSCOPIC145 reports
- COBRA 3910900093Stryker Corporation · Accessories, arthroscopic138 reports
- FirstPass 72290129Smith & Nephew, Inc. · Accessories, arthroscopic82 reports
- FirstPass 72290130Smith & Nephew, Inc. · Accessories, arthroscopic80 reports
- MITEK 242025Medos International Sàrl · ACCESSORIES,ARTHROSCOPIC61 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page