ACUFEX 7205517Recalls & reported problems
Smith & Nephew, Inc. · ACUFEX DIRECTOR DRILL GUIDE. REQUIRES 1 AIMER AND 1 BULLET NOT INCLUDED · Class 1
All models of ACUFEX (86)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 03596010373250), received between Feb 13, 2019 and Mar 18, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Defective Device1
- Device Markings/Labelling Problem1
- Failure to Align1
- Material Twisted/Bent1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Known Impact Or Consequence To Patient1
- No Patient Involvement1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 18, 2025Break; Break
IT WAS REPORTED THAT DURING AN ARTHROSCOPY, INSTRUMENTS OUTSIDE THE PATIENT, THE THREAD ON THE SCREW OF THE ACUFEX DIRECTOR DRILL GUIDE FUSED AND BROKE (THE SCREW HEAD BROKE). THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A SURGICAL DELAY OF LESS THAN 30 MINUTES USING THE SAME FAULTY DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21628260 ↗MalfunctionDec 17, 2020Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT THE ARROW ON THE ACL HANDLE HAS WORN OFF AND IT IS NO LONGER LEGIBLE; THEREFORE, IT IS IMPOSSIBLE TO SET THE ANGLE OF THE AIMER ACCURATELY. THE MALFUNCTION WAS FOUND DURING SET UP AND WAS SOLVED WITH NO DELAYS OR PATIENT HARM USING A BACK UP DEVICE. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11026659 ↗MalfunctionNov 1, 2020Failure to Align; Material Twisted/Bent; Failure to Align; Material Twisted/Bent
IT WAS REPORTED THAT DURING THE SET UP BEFORE THE SURGERY, IT WAS NOTICED AN INACCURACY OF THE TIBIA TIP AIMER, 4 POINT BULLET AND ACUFEX TIBIA TIP AIMER HAVE BEEN ALL SET UP, 2.4MM GUIDE PIN WAS USED AND IT WAS NOTICED THAT THE EXIT OF THE GUIDE DID NOT HIT THE TIP OF THE AIMER, IT SLIGHTLY DEVIATED TO THE TIP. NO PATIENT INJURIES OR DELAY REPORTED. SMITH AND NEPHEW BACK-UP DEVICE WAS AVAILABLE TO COMPLETE THE SURGERY. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Patient Involvement
MAUDE report 10767700 ↗MalfunctionFeb 13, 2019Defective Device
IT WAS REPORTED THAT THE DEVICE WAS DEFECTIVE. PRIOR TO DRILLING THE TIBIAL TUNNEL, WE COULD NOT ASSEMBLE THE GUIDE DUE TO THE FACT THAT THE BULLET WAS NOT ABLE TO SLIDE INTO THE GUIDE HANDLE. THE PROCEDURE WAS COMPLETED WITH A COMPETITOR DEVICE. NO PATIENT INJURIES WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8336020 ↗
Other ACCESSORIES,ARTHROSCOPIC devices
- Arthrex® AR-12990Arthrex, Inc. · Accessories, arthroscopic409 reports
- NA 228302Medos International Sàrl · ACCESSORIES,ARTHROSCOPIC287 reports
- FIRSTPASS 72290128Smith & Nephew, Inc. · ACCESSORIES,ARTHROSCOPIC232 reports
- NA 251723Medos International Sàrl · ACCESSORIES,ARTHROSCOPIC145 reports
- COBRA 3910900093Stryker Corporation · Accessories, arthroscopic138 reports
- FirstPass 72290129Smith & Nephew, Inc. · Accessories, arthroscopic82 reports
- FirstPass 72290130Smith & Nephew, Inc. · Accessories, arthroscopic80 reports
- MITEK 242025Medos International Sàrl · ACCESSORIES,ARTHROSCOPIC61 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.