TRIGEN 71637342Recalls & reported problems
Smith & Nephew, Inc. · TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 42CM LEFT · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010441225), received between Feb 9, 2022 and Feb 9, 2022 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K981529); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
- Product Quality Problem1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 9, 2022Break; Fracture; Product Quality Problem; Break; Fracture; Product Quality Problem
IT WAS REPORTED THAT DURING AN INTERNAL FIXATION SURGERY FOR A SUB-TROCHANTERIC FRACTURE, WHEN INSERTING THE TAN LIME 11.5X42 LF IN THE PATIENT'S MEDULLARY CANAL, THE DRILL BIT WENT OUT OF THE NAIL HOLE AND BROKE INSIDE THE PATIENT. THERE WAS A DELAY OF GREATER THAN 2 HOURS, WHILE THE END-USER TRIED TO REMOVE THE BROKEN PART, BUT IT WAS DIFFICULT AS IT WAS IN THE NECK OF THE FEMUR. HE HAD ALREADY SPENT A LONG TIME TRYING IN S+N TAN NAIL, SO HE DECIDED TO KEEP THE BROKEN PART AND FINISHED USING A COMPETITOR'S DEVICE. NO PATIENT HARM REPORTED, THE CURRENT HEALTH STATUS IS GOOD, AND THE FRACTURE HAS BEEN HEALING WELL.
Patient problems: Foreign Body In Patient
MAUDE report 13498826 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K981529. One submission often covers many models, so check the product and lot details in each record.
- Z-0944-2013 · Feb 7, 2013 · TerminatedINTERNAL HEX RECON SCREW, TI-6AL-4V, REF 7162375, TRIGEN (R) INTERNAL HEX CAPTURED RECON SCREW, QTY: (1), 6.4 MM, 75 MM, TITANIUM, Smith & Nephew, Inc. Orthopedic. Bone screw for
- Z-0943-2013 · Feb 7, 2013 · TerminatedINTERNAL HEX RECON SCREW, TI-6AL-4V, REF 7162380, TRIGEN (R) INTERNAL HEX CAPTURED RECON SCREW, QTY: (1), 6.4 MM, 80 MM, TITANIUM, Smith & Nephew, Inc. Orthopedic. Bone screw for
Other NAIL, FIXATION, BONE devices
- NA 03.043.024Synthes GmbH · NAIL, FIXATION, BONE234 reports
- NA 03.010.440Synthes GmbH · NAIL, FIXATION, BONE70 reports
- TRIGEN 71676627Smith & Nephew, Inc. · NAIL, FIXATION, BONE1 recall2 reports
- TRIGEN 71676628Smith & Nephew, Inc. · NAIL, FIXATION, BONE1 recall0 reports
- NA 03.043.018Synthes GmbH · NAIL, FIXATION, BONE33 reports
- TRIGEN 71675383Smith & Nephew, Inc. · NAIL, FIXATION, BONE29 reports
- NA 03.010.441Synthes GmbH · NAIL, FIXATION, BONE27 reports
- NA 03.010.435Synthes GmbH · NAIL, FIXATION, BONE24 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page