Skip to content

NA 71362753Recalls & reported problems

Smith & Nephew, Inc. · REFLECTION REAMER DOME 53MM · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010456915), received between Jul 18, 2020 and Mar 16, 2021 — classified as 2 injuries.

The most frequently reported specific device problem is “Break” (1 report).

2 other recalls cover devices cleared under the same FDA submission (K123598); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Most reported problems

Device problems

  • Break1
  • Flaked1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Injury1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 16, 2021Break; Break

    IT WAS REPORTED THAT, DURING A THR A REAMER DOME 53MM BROKE OFF WHILE REAMING THE ACETABULUM. THE PROCEDURE WAS COMPLETED WITH NO DELAYS AND A BACK UP DEVICE. NO INJURIES/HARM WERE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11497588 ↗
  • InjuryJul 18, 2020Flaked; Flaked

    IT WAS REPORTED THAT AFTER PROCEDURE IT WAS NOTICED THAT THE REAMER WAS SHEDDING METAL INSIDE THE PATIENT. NO DELAY. THE PROCEDURE WAS FINISHED USING THE SAME DEVICE.

    Patient problems: Injury; No Clinical Signs, Symptoms or Conditions

    MAUDE report 10293476 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K123598. One submission often covers many models, so check the product and lot details in each record.

  • Z-0730-2019 · Jan 7, 2019 · Terminated
    SL PLUS MIA DOUBLE OFFSET ADAPTER RIGHT 60/25MM, S&N 75004613
  • Z-1008-2017 · Nov 16, 2016 · Terminated
    REFLECTION(R) DEAD BLOW MALLET, REF 71362106, QTY: (1), NON-STERILE, Smith & Nephew, Inc,. Memphis, TN 38116

Other Prosthesis, hip, femoral component, cemented, metal devices

All Prosthesis, hip, femoral component, cemented, metal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page