TRIGEN 71754022Recalls & reported problems
Smith & Nephew, Inc. · TRIGEN 4.0MM X 22MM SELF-TAPPING CORTICAL SCREW TITANIUM · Class 2 · Implant
All models of TRIGEN (381)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010514288), received between Sep 20, 2020 and Sep 20, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Failure to Align” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K032722, K210980); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Failure to Align1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 20, 2020Failure to Align; Failure to Align
IT WAS REPORTED THAT WHEN USING THE SN DEVICE TRIGEN SCREW FOR HUMERAL NAILING, THE FIRST SCREW USED FOR DISTAL SCREWING BECAME UNSUITABLE FOR THE SCREWDRIVER THAT IS NORMALLY DESIGNED TO LOCK INTO THE SCREW. THE SCREW WHEN USED WAS THEN LOST INSIDE THE PATIENT'S ARM. IT WAS DIFFICULT TO REMOVE IT. AT FIRST, THE TEAM THOUGHT THAT THE SCREWDRIVER HAD BEEN MISUSED. THE PROCEDURE CONTINUED WITHOUT PROBLEMS FOR THE INSERTION OF THE OTHER SCREWS, UNTIL THE FIRST SCREW REMOVED WAS REUSED. THE SAME PROBLEM OCCURRED AGAIN: SCREW LOST IN THE PATIENT. THIS SCREW WAS SUCCESSFULLY REMOVED AGAIN. AFTER FURTHER OBSERVATION AND HANDLING, IT WAS FOUND THAT THE SCREW APPEARS TO HAVE A DEFECT THAT CAUSES IT TO DETACH AT AN ANGLE FROM THE SCREWDRIVER TO WHICH IT IS SUPPOSED TO BE FIRMLY ATTACHED. THERE WERE NO CONSEQUENCES FOR THE PATIENT DESPITE THE LONGER OPERATING TIME AND THE RISK OF INJURY DURING THE SEARCH FOR THE SCREW. SMITH AND NEPHEW BACKUP DEVICE WAS USED. IT IS UNKNOWN HOW LONG WAS THE DELAY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10558349 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K032722, K210980. One submission often covers many models, so check the product and lot details in each record.
- Z-2456-2026 · Mar 16, 2026 · Open, ClassifiedTRIGEN PROXIMAL STRAIGHT HUMERAL NAIL 8/7 X 16, REF: 71760816
- Z-1806-2025 · Mar 18, 2025 · Open, ClassifiedMETA-TAN LAG/COMPRESSION SCREW KIT 90MM/85MM, REF: 71642690
- Z-2443-2023 · Jul 24, 2023 · Open, ClassifiedTRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT, REF 71647336, Femur nail
- Z-2444-2023 · Jul 24, 2023 · Open, ClassifiedTRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 40CM 130 DEGREE LEFT, REF 71647340, Femur nail
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE Intramedullary Limb Lengthening System LSB5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page