Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010560896), received between Jul 31, 2018 and May 27, 2019 — classified as 2 injuries.

The most frequently reported specific device problem is “Fracture” (1 report).

6 other recalls cover devices cleared under the same FDA submission (K040212); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Fracture1
  • Insufficient Device Problem Information1
  • Migration1

Patient problems

  • Injury1
  • Intraoperative Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 27, 2019Fracture; Fracture

    IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED ON THE PATIENT DUE TO THE BREAKAGE OF THE INTERTAN NAIL.

    Patient problems: Injury

    MAUDE report 8643563 ↗
  • InjuryJul 31, 2018Insufficient Device Problem Information; Migration; Insufficient Device Problem Information; Migration

    IT WAS REPORTED A REVISION SURGERY IN WHICH THE COMPRESSION SCREW BACKED OFF THREE MONTHS POST-OP. THEY HAD TO REMOVE THE NAIL BECAUSE THE PROMINENT SCREW CAUSED PAIN. ALL PIECES WERE REMOVED.

    Patient problems: Intraoperative Pain

    MAUDE report 7737678 ↗

FDA clearance and classification

Cleared through Special 510(k) K040212 on Feb 20, 2004 (decision: Substantially Equivalent). Submitted by Smith & Nephew, Inc. as “Trigen Intertan”. The FDA review took 21 days. FDA record ↗

The FDA regulates product code JDS (nail, fixation, bone) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K040212. One submission often covers many models, so check the product and lot details in each record.

  • Z-1133-2022 · Apr 22, 2022 · Open, Classified
    INTERTAN 1.5 NAIL 13mm X 42cm 130DEG. Left INTERTAN 1.5 NAIL 13mm X 42cm 130DEG. Right
  • Z-0772-2021 · Nov 2, 2020 · Terminated
    Bone fixation nail. TRIGEN INTERTAN - Product Usage: indicated for fractures of the femur including simple shaft fractures, comminuted shaft fractures, spiral shaft fractures, long
  • Z-0097-2018 · Oct 24, 2017 · Open, Classified
    smith&nephew TRIGEN INTERTAN 10S, REF 71675384, 10 MM X 18 CM NAIL, 130o (degrees), SET SCREW PREASSEMBLED IN NAIL
  • Z-2258-2014 · Jul 2, 2014 · Terminated
    TRIGEN(R) INTERTAN(TM) 10MM X 18 CM NAIL, 125o, REF 71675201, QTY (1), STERILE R, Smith & Nephew, Memphis, Inc., TN 38116 TRIGEN(R) INTERTAN(TM) 11.5MM X 18 CM NAIL, 125o, REF
  • Z-1637-2014 · Apr 4, 2014 · Terminated
    TRIGEN INTERTAN 1.5 NAIL: (1) REF 71676515, 10 MM X 10 CM, 125 degree, LEFT, (2) REF 71676556, 11.5 MM X 36 CM, 125 degree, RIGHT, (3) REF 71676558, 11.5 MM X 38 CM, 125 degree
  • Z-1636-2014 · Apr 4, 2014 · Terminated
    TRIGEN INTERTAN NAIL: (1) REF 71675201, 10 MM X 18 CM, 125 degree, (2) REF 71675202, 11.5 MM X 18 CM, 125 degree, (3) REF 71675203, 13 MM X 18 CM, 125 degree, (4) REF 71675204,

Common questions about the TRIGEN 71675266

Has the TRIGEN 71675266 been recalled?

No FDA recall record in our data names this exact device identifier (DI 03596010560896), based on the FDA recall file dated Nov 27, 2026. However, 6 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the TRIGEN 71675266?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Jul 31, 2018 and May 27, 2019. In those reports, the most common specific device problems are “Fracture” (1) and “Migration” (1); the most common patient problems are “Injury” (1) and “Intraoperative Pain” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the TRIGEN 71675266?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the TRIGEN 71675266 FDA approved?

It was cleared through Special 510(k) K040212 on Feb 20, 2004. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the TRIGEN 71675266 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the TRIGEN 71675266, and is it still sold?

The FDA's device database lists Smith & Nephew, Inc. as the company responsible for it (brand TRIGEN, model 71675266). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other NAIL, FIXATION, BONE devices

All NAIL, FIXATION, BONE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page