JOURNEY 71422266Recalls & reported problems
Smith & Nephew, Inc. · JOURNEY UNI TIBIA INSERT SIZE 5-6RIGHT MEDIAL/LEFT LATERAL 9MM · Class 2 · Implant
All models of JOURNEY (565)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 03596010582256), received between Oct 16, 2018 and Feb 14, 2024 — classified as 4 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K061011, K230653); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Insufficient Device Problem Information2
Patient problems
- Injury2
- Insufficient Information1
- Medical device site infection1
- Unspecified Infection1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryFeb 14, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, AFTER A PRIMARY UKA PERFORMED ON (B)(6) 2023, THE PATIENT PRESENTED AN INFECTION. A REVISION SURGERY WAS PERFORMED ON (B)(6) 2024 TO SOLVE THE ISSUE. THE WOUND WAS WASHED AND DEBRIDED THOROUGHLY. THE INSERT DID NOT HAVE ANY VISIBLE DEFECTS, BUT IT WAS EXPLANTED AND REPLACED FOR ANOTHER S+N INSERT OF THE SAME SIZE. THE PATIENT CURRENT HEALTH STATUS IS CURRENTLY UNKNOWN.
Patient problems: Medical device site infection; Unspecified Infection
MAUDE report 18707233 ↗InjuryMar 15, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, AFTER A RIGHT MEDIAL UNICOMPARTMENTAL KNEE REPLACEMENT HAD BEEN PERFORMED ON (B)(6)2020 TO ADDRESS A MEDIAL GONARTHROSIS SYMPTOMS, THE PATIENT REQUIRED A REVISION SURGERY ON (B)(6)2020 DUE TO A WOUND HEALING DISORDER WHERE THE TIBIAL INSERT WAS EXCHANGED. THE OUTCOME OF THIS PATIENT IS UNKNOWN. THIS INCIDENT WAS NOTICED IN A RETROSPECTIVE POST-MARKET CLINICAL FOLLOW UP ACTIVITY (PMCF) WHERE ANONYMIZED DATA SUMMARIZING OUTCOMES WERE GATHERED RETROSPECTIVELY; THEREFORE, ADDITIONAL INFORMATION IS NOT KNOWN.
Patient problems: Insufficient Information
MAUDE report 16542730 ↗InjuryFeb 22, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT 5 MONTHS AFTER KNEE REPLACEMENT, A REVISION SURGERY WAS PERFORMED DUE TO UNSPECIFIED REASONS.
Patient problems: Injury
MAUDE report 8362175 ↗InjuryOct 16, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT THE UNI IMPLANTS FAILED AS PER SURGEON DR. (B)(6). REVISION SURGERY PERFORMED TO EXPLANT DEVICES. UNABLE TO SEE LOTS DUE TO BONE INGROWTH.
Patient problems: Injury
MAUDE report 7970321 ↗
FDA clearance and classification
Cleared through 510(k) K230653 on May 4, 2023 (decision: Substantially Equivalent). Submitted by Smith & Nephew, Inc. as “Smith & Nephew, Inc. ANTHEM Total Knee System, Genesis Uni Knee System, JOURNEY BCS and II Knee Systems, JOURNEY II CR Knee System, JOURNEY II Uni Knee System, Journey II UK Knee System, JOURNEY II XR Bi-Cruciate Retaining Knee System, JOURNEY PFJ System, JOURNEY Uni Knee System, Legion Hinge Total Knee System, Legion Total Knee System, ZUK Unicompartmental Knee System, ENGAGE Partial Knee System and Porous Patella and Porous Tibial Baseplates”. The FDA review took 56 days. FDA record ↗
Cleared through Abbreviated 510(k) K061011 on Jul 11, 2006 (decision: Substantially Equivalent). Submitted by Smith & Nephew, Inc. as “Competitor Unicondylar Knee Tibial Baseplate”. The FDA review took 90 days. FDA record ↗
The FDA regulates product code HSX (prosthesis, knee, femorotibial, non-constrained, cemented, metal/polymer) under 21 CFR 888.3520 as a Class II device. 21 CFR 888.3520 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K061011, K230653. One submission often covers many models, so check the product and lot details in each record.
- Z-2621-2023 · Aug 31, 2023 · Open, Classifiedsmith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint
Common questions about the JOURNEY 71422266
Has the JOURNEY 71422266 been recalled?
No FDA recall record in our data names this exact device identifier (DI 03596010582256), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the JOURNEY 71422266?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Oct 16, 2018 and Feb 14, 2024. In those reports, the most common patient problems are “Injury” (2), “Medical device site infection” (1) and “Unspecified Infection” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the JOURNEY 71422266?
None of the reports are classified as deaths, 4 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the JOURNEY 71422266 FDA approved?
It was cleared through Abbreviated 510(k) K061011 on Jul 11, 2006; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the JOURNEY 71422266 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the JOURNEY 71422266, and is it still sold?
The FDA's device database lists Smith & Nephew, Inc. as the company responsible for it (brand JOURNEY, model 71422266). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page