TRIGEN 71655033Recalls & reported problems

Smith & Nephew, Inc. · TRIGEN META TIBIAL NAIL 8.5MM X 33CM · Class 2 · Implant

All models of TRIGEN (380)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010585486), received between Apr 16, 2023 and Apr 16, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Failure to Align” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Failure to Align1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 16, 2023Failure to Align; Failure to Align

    IT WAS REPORTED THAT DURING TRAUMA SURGERY, THE MEDULLARY CANAL HAD BEEN PREVIOUSLY RIMMED AND ONE (1) META-NAIL TIBIAL 8.5MM X 33CM WAS PLACED, AN ATTEMPT WAS MADE TO BLOCK DISTALLY WITH SURESHOT AND UNDER FLUOROSCOPY BUT IT WAS NOT POSSIBLE TO PLACE THE SCREW AFTER SEVERAL ATTEMPTS. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, USING A DIFFERENT SIZE S+N BACK-UP DEVICE. PATIENT WAS NOT HARMED AS CONSEQUENCE OF THIS PROBLEM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16748735 ↗

FDA clearance and classification

The FDA regulates product code JDS (nail, fixation, bone) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the TRIGEN 71655033

Has the TRIGEN 71655033 been recalled?

No FDA recall record in our data names this exact device identifier (DI 03596010585486), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the TRIGEN 71655033?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 16, 2023. That report lists device problem “Failure to Align” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the TRIGEN 71655033?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the TRIGEN 71655033 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the TRIGEN 71655033, and is it still sold?

The FDA's device database lists Smith & Nephew, Inc. as the company responsible for it (brand TRIGEN, model 71655033). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other NAIL, FIXATION, BONE devices

All NAIL, FIXATION, BONE devices →