Skip to content

BIORAPTOR 72202404Recalls & reported problems

Smith & Nephew, Inc. · BIORAPTOR TWIST DRILL, 2.9 MM INLINE · Class 1

All models of BIORAPTOR (12)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010652409), received between Jun 8, 2021 and Jun 8, 2021 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 8, 2021Break; Break

    IT WAS REPORTED THAT THE DRILL BIT BROKE ON THE FISH LIP DURING THE DISLOCATION OF SHOULDER JOINT PROCEDURE, SOME PIECES REMAIN IN THE BONE, AND FINALLY PIECES WERE REMOVED. THE PROCEDURE WAS COMPLETED WITH A SMITH AND NEPHEW BACKUP DEVICE. THERE WAS A DELAY GREATER THAN 30 MIN. NO OTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11963348 ↗

Other ACCESSORIES,ARTHROSCOPIC devices

All ACCESSORIES,ARTHROSCOPIC devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page