Skip to content

Porges Coloplast AB6020Recalls & reported problems

Coloplast A/S · X-FLOW® Prostatectomy catheter straight tip 3-way 30-50 ml 100% silicone CH FR 20 · Class 2

All models of Porges Coloplast (79)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03600040143230), received between Aug 22, 2018 and Oct 31, 2023 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Deflation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Deflation Problem1
  • Failure to Deflate1

Patient problems

  • Hematuria1
  • No Clinical Signs, Symptoms or Conditions1
  • Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 31, 2023Failure to Deflate; Failure to Deflate

    ACCORDING TO THE AVAILABLE INFORMATION DURING TESTING OF THE CATHETER OUTSIDE THE PATIENT, THE BALLOON WAS VERY HARD TO INFLATE AND IMPOSSIBLE TO DEFLATE. THE BALLOON WAS INFLATED WITH A 50ML SYRINGE AND STERILE WATER. A NEW CATHETER WAS USED TO COMPLETE THE CASE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18040461 ↗
  • InjuryAug 22, 2018Deflation Problem; Deflation Problem

    ACCORDING TO THE AVAILABLE INFORMATION, THE BALLOON DEFLATES OR IS PIERCED ONE WEEK FOLLOWING PLACEMENT OF THE CATHETER. NEED TO CHANGE THE CATHETER OF THE PATIENT MORE OFTEN THAN NORMAL. THIS OCCURED SEVERAL TIMES. CONSEQUENCE: HEMATURIA, PAINS.

    Patient problems: Hematuria; Pain

    MAUDE report 7804411 ↗

Other CATHETER, RETENTION TYPE, BALLOON devices

All CATHETER, RETENTION TYPE, BALLOON devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page