AEQUALIS REVERSED II DWD170Recalls & reported problems

Tornier · Class 2 · Implant

All models of AEQUALIS REVERSED II (46)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
15
Deaths reported
0
Injuries reported
15
Recalls naming it
0

Summary

The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 03700386935947), received between Mar 24, 2017 and Sep 4, 2024 — classified as 15 injuries.

The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem10
  • Loosening of Implant Not Related to Bone-Ingrowth4
  • Device Dislodged or Dislocated2
  • Missing Value Reason2
  • Disassembly1
  • Material Fragmentation1
  • Mechanical Problem1
  • Migration1

Patient problems

  • Patient Problem/Medical Problem5
  • Unspecified Infection5
  • Joint Dislocation3
  • Failure of Implant1
  • Implant Pain1
  • Joint Disorder1
  • Pain1

Recent adverse event reports

The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.

  • InjurySep 4, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "THE DETAILS ARE UNKNOWN, THE PRIMARY SURGERY FOR ARTIFICIAL SHOULDER JOINT REPLACEMENT WAS PERFORMED AT ANOTHER HOSPITAL ABOUT 6 YEARS AGO. ABOUT 2 YEARS AGO, THE PERIPROSTHETIC SHOULDER JOINT FRACTURE AROUND THE ARTIFICIAL SHOULDER JOINT WAS OCCURRED AND PERFORMED THE PLATING SURGERY. AFTER PLATING SURGERY, THE SURGERY FOR REMOVING THE PLATE AND SCREWS WAS PERFORMED DUE TO INFECTION. ON (B)(6) 2024, THE SURGERY FOR REMOVING ARTIFICIAL SHOULDER JOINT WAS PERFORMED DUE TO THE INFECTION AROUND THE STEM".

    Patient problems: Unspecified Infection

    MAUDE report 20133386 ↗
  • InjuryOct 10, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED IN A LAWSUIT THAT THE PATIENT REPORTED HAVING REFRACTORY PAIN AND DYSFUNCTION OF THE SHOULDER WHICH WAS REFRACTORY TO CONSERVATIVE MEASURES. PREOPERATIVE IMAGING WAS SUGGESTIVE OF LOOSENING OF THE HUMERAL COMPONENT, SPECIFICALLY AT THE JUNCTION OF THE PROXIMAL HUMERAL BODY TO THE HUMERAL STEM AT THE ASSEMBLY SCREW JUNCTION.

    Patient problems: Implant Pain

    MAUDE report 17906599 ↗
  • InjuryFeb 25, 2022Material Fragmentation; Loosening of Implant Not Related to Bone-Ingrowth; Migration; Material Fragmentation; Loosening of Implant Not Related to Bone-Ingrowth; Migration

    "IT WAS REPORTED, DURING 5YFU, THAT A PATIENT HAD A GLENOID LOOSENING (XRAYS SHOW A BROKEN SCREW AND APPARENT UPWARD MIGRATION OF GLENOSPHERE). PATIENT ID: (B)(6)".

    Patient problems: Failure of Implant

    MAUDE report 13607017 ↗
  • InjuryFeb 9, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT (B)(6) UNDERWENT A REVISION SURGERY DUE TO DEEP INFECTION. REMOVAL OF AEQUALIS ASCEND FLEX HUMERAL COMPONENTS (STEM, TRAY AND INSERT) AND AEQUALIS REVERSED GLENOID COMPONENTS (BASEPLATE AND GLENOSPHERE). PRIOR SURGERIES ON STUDY SHOULDER: ROTATOR CUFF REPAIR, ACROMIOPLASTY, DISTAL CLAVICLE RESECTION.

    Patient problems: Unspecified Infection

    MAUDE report 13497193 ↗
  • InjurySep 1, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2017, THIS PATIENT HAD AN INITIAL SURGERY OF AEQUALIS REVERSE AT (B)(6) ORTHOPEDICS HOSPITAL. ON (B)(6) 2020, AN INFECTION WAS FOUND AT THE AFFECTED PART AT THE SAME HOSPITAL. ON (B)(6) 2020, A REVISION SURGERY WAS PERFORMED AT (B)(6) MEDICAL CENTER. AFTER REMOVING ALL THE IMPLANTS,THE MOLD CEMENT WHICH INCLUDES ANTIBIOTICS WAS IMPLANTED TO THE HUMERAL AND THE SURGERY WAS COMPLETED. AFTER SEVERAL MONTHS OF FOLLOW-UP, ANOTHER REVISION SURGERY MIGHT BE PERFORMED FOR NEW IMPLANTS DEPENDING ON THE RECOVERY SITUATION.

    Patient problems: Unspecified Infection

    MAUDE report 10475818 ↗
  • InjuryJul 9, 2020Adverse Event Without Identified Device or Use Problem; Loosening of Implant Not Related to Bone-Ingrowth; Adverse Event Without Identified Device or Use Problem; Loosening of Implant Not Related to Bone-Ingrowth

    AFTER THIS PATIENT HAD A ASCEND FLEX REVERSE SURGERY ON (B)(6) 2020, A DISLOCATION OCCURRED AT THE AFFECTED AREA. ON (B)(6) 2020, AN IMPLANT AT THE AFFECTED AREA WAS REPLACED AND THE SURGERY WAS FINISHED.

    Patient problems: Joint Dislocation; Joint Disorder

    MAUDE report 10249653 ↗
  • InjuryFeb 13, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    "(B)(6) 2017: THE INITIAL SURGERY OF ""AEQUALIS REVERSE"" AND ""AEQUALIS ASCEND FLEX REVERSE"" WERE PERFORMED. SPRING, 2018: THERE WAS A LEG FRACTURE. (B)(6) 2019: THE AFFECTED AREA GOT DISLOCATED AND THE REVISION SURGERY WAS SCHEDULED. (B)(6) 2020: THE REVISION SURGERY WAS PERFORMED. ALL THE IMPLANTS WERE REMOVED EXCEPT THE STEM, AND THE HEAD IMPLANT (DWF043) WAS NEWLY ATTACHED TO THE STEM. THE ILIAC BONE WAS IMPLANTED INTO THE GLENOID CAVITY, AND THE OPERATION WAS COMPLETED. THE SURGEON COMMENTED. ""AFTER THE FRACTURE OF THE LOWER LEG, WE RECOMMENDED TO MOVE ON A WHEELCHAIR THAT DID NOT APPLY A LOAD FROM BELOW, BUT THIS WAS PROBABLY DUE TO THE USE OF A WALKER AT THE REQUEST OF THE PATIENT. THERE WAS NO PROBLEM WITH THE IMPLANT.""

    Patient problems: Joint Dislocation

    MAUDE report 9705802 ↗
  • InjuryFeb 7, 2019Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE INITIAL SURGERY ON THE LEFT SHOULDER WAS HELD ON (B)(6) 2018. THE BASE PLATE WAS DISLOCATED ON (B)(6) 2019, AND REVISION SURGERY WAS PERFORMED ON (B)(6) 2019. ON (B)(6), THE FRACTURE OF THE GLENOID CAVITY DUE TO DISLOCATION WAS CONFIRMED DURING REVISION SURGERY. THE BONE GRAFT WAS DONE IN THE GLENOID CAVITY, AND THE HUMERUS SIDE WAS TREATED WITH A CEMENT TYPE CONTAINING ANTIBIOTICS. AFTER ABOUT SIX MONTHS FOLLOW-UP, THE SURGEON WILL DECIDE WHETHER TO REPLACE THE BASE PLATE WHILE WATCHING THE RECOVERY STATUS OF THE BONE.

    Patient problems: Joint Dislocation

    MAUDE report 8315276 ↗
  • InjuryDec 13, 2018Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    "IT WAS REPORTED THAT A PATIENT HAD A GLENOID COMPONENTS' LOOSENING 9 MONTHS POST-OPERATIVE. PATIENT ID: (B)(6)".

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 8159456 ↗
  • InjuryJul 12, 2018Mechanical Problem; Device Dislodged or Dislocated; Mechanical Problem; Device Dislodged or Dislocated

    "IT WAS REPORTED THAT A PATIENT UNDERWENT A REVISION SURGERY FOR DISSOCIATION 1 YEAR POST-OPERATIVE. PATIENT ID : (B)(6)".

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 7681372 ↗
  • InjuryMay 18, 2018Adverse Event Without Identified Device or Use Problem; Loosening of Implant Not Related to Bone-Ingrowth; Adverse Event Without Identified Device or Use Problem; Loosening of Implant Not Related to Bone-Ingrowth

    (B)(6) 2015: INITIAL RSA SURGERY. / (B)(6) 2015: OBSERVED BONE RESORPTION BY NOTCHING IN X-RAY AT 6 MONTHS CHECK. / (B)(6) 2016: SEEMS THE BONE RESORPTION HAS STOPPED. / (B)(6) 2018: GLENOID COMPONENT ELIMINATION. BONE GRAFTING.

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 7525297 ↗
  • InjuryFeb 1, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    "(B)(6) 2017: INITIAL RSA SURGERY WAS DONE. / (B)(6) 2017: GLENOID SPHERE DISLOCATION WAS FOUND. (THE PATIENT HAD BEEN UNABLE TO LIFT HER SHOULDER.) / (B)(6) 2017: GLENOID SPHERE, BASEPLATE, 4 SCREWS, INSERT AND TRAY WERE REMOVED. COMMENTS FROM SURGEON: THE PATIENT'S BONE DENSITY HAD BEEN VERY LOW WHICH MAY HAVE CAUSED THE GLENOID SPHERE DISLOCATION. "

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 7233747 ↗
  • InjuryNov 21, 2017Disassembly; Disassembly

    THE SPHERE AND BASEPLATE HAD BECOME LOOSENED AND SPHERE AND INSERT WERE REPLACED WITH NEW ONES. THE SURGEON SAID THAT THE SCREWS IN THE SPHERE WERE NOT TIGHTENED ENOUGH AT THE INITIAL OPERATION.

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 7048097 ↗
  • InjuryMay 10, 2017Adverse Event Without Identified Device or Use Problem; Missing Value Reason; Adverse Event Without Identified Device or Use Problem; Missing Value Reason

    SINCE THE PATIENT HAD INFECTION, ALL IMPLANTS WERE REMOVED AND THE INSERTION SITE WAS FILLED WITH A CEMENT CONTAINING ANTIBIOTICS. THE PATIENT RECEIVED CONSERVATIVE TREATMENT.

    Patient problems: Unspecified Infection

    MAUDE report 6556614 ↗
  • InjuryMar 24, 2017Adverse Event Without Identified Device or Use Problem; Missing Value Reason; Adverse Event Without Identified Device or Use Problem; Missing Value Reason

    THE PATIENT COMPLAINED PAIN 16 MONTHS AFTER THE OPERATION AND THE PATIENT WAS TREATED WITH INTRA-ARTICULAR CLEANSING AND ANTIBIOTICS FOR 6 MONTHS BUT SINCE THERE WAS NO IMPROVEMENT, ALL THE DEVICES WERE REMOVED.

    Patient problems: Pain; Unspecified Infection

    MAUDE report 6432122 ↗

Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices

All PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page