Tornier Perform® Anatomic Glenoid DWE503Recalls & reported problems
Tornier · Keeled Glenoid · Class 2 · Implant
All models of Tornier Perform Anatomic Glenoid (25)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 03700434019186), received between Jun 8, 2022 and Aug 13, 2023 — classified as 3 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Device Dislodged or Dislocated1
- Material Fragmentation1
Patient problems
- Implant Pain2
- Failure of Implant1
- Foreign Body In Patient1
- Joint Dislocation1
- Muscle/Tendon Damage1
- Swelling/ Edema1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryAug 13, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN (B)(6) 2012 ¿ (B)(6) 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2019 A PATIENT REQUIRED REVISION SURGERY DUE TO DISLOCATION/SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Joint Dislocation
MAUDE report 17537967 ↗InjuryJan 6, 2023Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THERE WAS A PATIENT UNDERWENT A TOTAL SHOULDER REPLACEMENT. DURING SURGERY, SURGEON NOTED THAT A TENDONOUS TEAR OF THE JUNCTION OF THE SUPRASPINATUS AND SUBSCAPULARIS TENDONS EXISTED. SURGEON PERFORMED A REPAIR USING ANCHORS. POST-OP REHABILITATION PROCEEDED WITHOUT INCIDENT. HOWEVER, SEVERAL MONTHS FOLLOWING PRIMARY SURGERY, PATIENT COMPLAINED OF INCREASING PAIN, SWELLING AND INSTABILITY OF SHOULDER JOINT. SURGEON PERFORMED A SHOULDER ARTHROSCOPY, TO DISCOVER FULL THICKNESS TEARS OF BOTH OF THE AFORE MENTIONED TENDONS. DISCUSSED WITH THE PATIENT, WHERE A DECISION WAS MADE TO CONVERT THE SURGERY TO A REVERSE SHOULDER REPLACEMENT. DURING SURGERY TODAY, BOTH HUMERAL AND GLENOID COMPONENTS WERE REMOVED, AS PER THE RECOMMENDED SURGICAL TECHNIQUE. THE SURGEON HAS NO EXPLANATION AS TO WHY THE PATIENT'S ROTATOR CUFF TENDONS DETERIORATED IN SUCH A SHORT PERIOD OF TIME, RENDERING THE PROSTHETIC JOINT UNSTABLE, OTHER THAN HIS BELIEF THAT MICROSCOPIC POLY DEBRIS MAY HAVE SET UP AN INFLAMMATORY LOCAL RESPONSE THAT INHIBITED THE TENDON TEAR TO HEAL. ALL COMPONENTS DISCARDED.
Patient problems: Failure of Implant; Foreign Body In Patient; Implant Pain; Swelling/ Edema
MAUDE report 16118410 ↗InjuryJun 8, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT NOTICED PAIN AFTER PHYSICAL THERAPY POST-OPERATIVE ROTATOR CUFF TEAR . THE MRI SHOWS A LESSER TUBEROSITY AVULSION AND SUBSCAPULARIS TEAR. THE PATIENT UNDERWENT AN OPEN ROTATOR CUFF REPAIR WITH SUPERIOR CUFF RECONSTRUCTION USING ARTHOFLEX ALLOGRAFT. THE EVENT WAS RESOLVED WITHOUT SEQUELAE.
Patient problems: Implant Pain; Muscle/Tendon Damage
MAUDE report 14633198 ↗
Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices
- DJO SURGICAL 508-32-204Encore Medical, L.P. · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 recall544 reports
- Comprehensive Reverse Shoulder 010000589Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 recall142 reports
- DELTA XTEND 130738203Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED175 reports
- DJO SURGICAL 509-00-432Encore Medical, L.P. · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented1 recall117 reports
- Alliance® SBGL3007Zimmer, Inc. · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED162 reports
- DELTA XTEND 130760138Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED146 reports
- DELTA XTEND 130790030Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED132 reports
- DJO SURGICAL 509-00-436Encore Medical, L.P. · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented124 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page