Tornier Flex Shoulder System DWH043Recalls & reported problems

Tornier · Tornier Pyrocarbon Humeral Head · Class 2 · Implant

All models of Tornier Flex Shoulder System (91)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 03700434019469), received between May 9, 2023 and Sep 18, 2026 — classified as 5 injuries.

The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Damaged by Another Device1
  • Device Dislodged or Dislocated1
  • Naturally Worn1

Patient problems

  • Implant Pain2
  • Bacterial Infection1
  • Erosion1
  • Failure of Implant1
  • Insufficient Information1
  • Loss of Range of Motion1
  • Subluxation1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjurySep 18, 2026Adverse Event Without Identified Device or Use Problem

    The manufacturer received a report from the National Joint Registry that contains unpublished collected data on the usage and the outcomes of the shoulder joint replacement. The report details analysis provided for revision procedures performed (b)(6) 2026.During the review of the report, it was identified that on (b)(6)2026 a patient required revision surgery due to native glenoid surface erosion & unexplained pain, which was not previously reported to the manufacturer.

    Patient problems: Erosion

    MAUDE report 50813793 ↗
  • InjurySep 8, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT A PATIENT REQUIRED REVISION SURGERY DUE TO DISLOCATION/SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Subluxation

    MAUDE report 22993199 ↗
  • InjuryApr 15, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "PATIENT UNDERWENT SHOULDER HEMI-ARTHROPLASTY ON (B)(6) 2023, FOR FRACTURE PROXIMAL RIGHT HUMERUS. PATIENT HAS EXPERIENCED PAIN AND REDUCED RANGE OF MOTION OVER RECENT MONTHS. SURGEON SUSPECTS JOINT IS INFECTED, DUE TO 1 X SWAB RETURNING POSITIVE FOR BACTERIA C.ACNES. SURGEON HAS DECIDED ON A 2-STAGE REVISION ARTHROPLASTY. HUMERAL PROSTHESIS REMOVED, WITH SIGNIFICANT DIFFICULTY (HUMERAL STEM WELL FIXED). MULTIPLE TISSUE SPECIMENS TAKEN. EXPLANTED PROSTHESIS DISCARDED. CEMENT ANTIBIOTIC SPACER IMPLANTED."

    Patient problems: Bacterial Infection; Implant Pain; Loss of Range of Motion

    MAUDE report 19105750 ↗
  • InjuryOct 23, 2023Naturally Worn; Naturally Worn

    AS REPORTED: "AN ASCEND FLEX PYROCARBON HEAD WAS REVERSED TO A TOTAL ANATOMICAL CONSTRUCT. THE PYROCARBON HEAD WAS REMOVED EASILY AND WITH MINIMAL WEAR. REVISION PROCEDURE." UPDATED: REPORTED PATIENT COMPLAINT WAS PAIN. ASCEND FLEX STANDARD HEAD WITH PERFORM GLENOID HAS BEEN REIMPLANTED. IT WAS A LEFT SIDE SHOULDER.

    Patient problems: Failure of Implant; Implant Pain

    MAUDE report 17988950 ↗
  • InjuryMay 9, 2023Device Damaged by Another Device; Device Damaged by Another Device

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY DUE TO A SCREW FROM A PRIOR SURGERY RUBBING AGAINST PYROCARBON HUMERAL HEAD CAUSING DAMAGE TO THE HUMERAL HEAD. THE SURGEON REMOVED THE HUMERAL HEAD AND SWITCHED TO A FLEX REVERSE CONSTRUCT BECAUSE THE GLENOID WAS STRONGLY ANTEVERTED AND THEREFORE HE THOUGHT THAT AN ANATOMICAL ONE WOULD NOT HAVE BEEN STABLE.

    Patient problems: Insufficient Information

    MAUDE report 16898427 ↗

Other Shoulder joint humeral (hemi-shoulder) ceramic head/metallic stem cemented or uncemented prosthesis devices

All Shoulder joint humeral (hemi-shoulder) ceramic head/metallic stem cemented or uncemented prosthesis devices →