Skip to content

Tornier Flex Shoulder System DWH139Recalls & reported problems

Tornier · Tornier Pyrocarbon Humeral Head · Class 2 · Implant

All models of Tornier Flex Shoulder System (91)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 03700434019643), received between Oct 22, 2023 and Mar 5, 2026 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Fracture” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture2
  • Off-Label Use2
  • Break1
  • Device Dislodged or Dislocated1

Patient problems

  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1
  • Subluxation1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 5, 2026Off-Label Use; Device Dislodged or Dislocated

    IT WAS REPORTED THAT, THE PATIENT HAD REVISION SURGERY OF REVIVE STEM WITH PYROCARBON HEAD. IT WAS A CONVERSION TO REVERSE AFTER RECURRENT DISLOCATIONS. ITEMS WERE INTACT AND REMOVED SAFELY. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Subluxation

    MAUDE report 24521622 ↗
  • MalfunctionJan 8, 2026Fracture; Off-Label Use

    IT WAS REPORTED THAT, PYROCARBON HEAD CHIPPED BY SURGEON DURING REMOVAL OF OSTEOPHYTES AROUND THE IMPLANT. IMPLANT WAS FULLY INTACT PRIOR TO ATTEMPTING REMOVAL. NO FURTHER INFORMATION WAS REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 24005278 ↗
  • MalfunctionOct 22, 2023Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT THE IMPLANT WAS FOUND BROKEN WHEN THE BOX WAS OPENED. THE LOW OFFSET VERSION OF THE SAME DIAMETER AND HEIGHT WITH NO NOTED COMPROMISE TO THE FIT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17982331 ↗

Other Shoulder joint humeral (hemi-shoulder) ceramic head/metallic stem cemented or uncemented prosthesis devices

All Shoulder joint humeral (hemi-shoulder) ceramic head/metallic stem cemented or uncemented prosthesis devices →

Sources and updates