Tornier · Class 2 · Implant

All models of Tornier Flex Shoulder System (91)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 03700434020229), received between Dec 29, 2022 and Jul 3, 2024 — classified as 5 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated4
  • Adverse Event Without Identified Device or Use Problem1
  • Osseointegration Problem1
  • Unstable1

Patient problems

  • Joint Dislocation4
  • Subluxation2
  • Implant Pain1
  • Unspecified Infection1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 3, 2024Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem; Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THERE WAS A THIRD REVISION SHOULDER REPLACEMENT SURGERY PERFORMED ON A PATIENT WITH RECURRENT DISLOCATIONS. THIS WAS THE FOURTH SURGERY ON THE SAME SHOULDER. ALL HUMERAL COMPONENTS (STEM, TRAY, POLY) WERE REMOVED AND REPLACED: A 2B STANDARD STEM WAS REPLACED WITH A 3C STANDARD STEM, A HIGH OFFSET +6 TRAY WAS REPLACED WITH A HIGH OFFSET +12 TRAY, AND A FLEX REVERSED INSERT B +9 WAS REPLACED WITH A FLEX REVERSED INSERT B +9 RETENTIVE. THE GLENOID IMPLANTS WERE LEFT INTACT.

    Patient problems: Joint Dislocation

    MAUDE report 19671177 ↗
  • InjuryJun 24, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THIS EVENT IS REPORTABLE TO REVISION SURGERY THAT THE PATIENT UNDERWENT ON THE SAME SHOULDER DUE TO RECURRENT DISLOCATIONS. THIS EVENT WILL BE FILED AS A SERIOUS INJURY. THIS MDR IS TO DOCUMENT THE SECOND REVISION SURGERY.

    Patient problems: Joint Dislocation

    MAUDE report 19596041 ↗
  • InjuryMar 25, 2024Unstable; Device Dislodged or Dislocated; Unstable; Device Dislodged or Dislocated

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2020 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION/INSTABILITY/ASEPTIC LOOSENING HUMERUS/DISLOCATION/SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Joint Dislocation; Subluxation; Unspecified Infection

    MAUDE report 18967334 ↗
  • InjuryFeb 29, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2020 A PATIENT REQUIRED REVISION SURGERY DUE TO DISLOCATION/SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: SINGLE STAGE REVISION.

    Patient problems: Joint Dislocation; Subluxation

    MAUDE report 18813060 ↗
  • InjuryDec 29, 2022Osseointegration Problem; Osseointegration Problem

    IT WAS REPORTED THAT THE PATIENT HAD SIGNIFICANT PAIN. FOLLOWING IMPLANT LOOSENING OR FAILURE, PATIENT UNDERWENT REVISION SURGERY ON (B)(6) 2021. REPORTS OF COMPLEX REGIONAL PAIN SYNDROME IN AUGUST 2020. IN MAY 2021 PATIENT'S X-RAYS REVEAL RADIOLUCENT LINES AND/OR BONY RESORPTION CONSISTENT WITH IMPLANT LOOSENING OR FAILURE. PATIENT CONTINUES TO HAVE SIGNIFICANT PAIN AND FUNCTIONAL LIMITATIONS IN SPITE OF NON OPERATIVE MANAGEMENT.

    Patient problems: Implant Pain

    MAUDE report 16069795 ↗