Tornier Perform® Anatomic Glenoid DWE312Recalls & reported problems

Tornier · Pegged Glenoid · Class 2 · Implant

All models of Tornier Perform Anatomic Glenoid (25)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 03700434022278), received between May 12, 2023 and Feb 6, 2026 — classified as 6 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Dislodged or Dislocated2
  • Migration1
  • Naturally Worn1
  • Osseointegration Problem1

Patient problems

  • Implant Pain2
  • Joint Dislocation1
  • Limb Fracture1
  • Muscle/Tendon Damage1
  • No Clinical Signs, Symptoms or Conditions1
  • Osteolysis1
  • Pain1
  • Subluxation1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 6, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, THE PATIENT HAD PAIN. IT WAS ALSO REPORTED. (B)(6) TEAM WERE USED FOR THEIR STEM ONCE THE AEQUALIS AND PERFORM PEGGED WAS REMOVED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Pain

    MAUDE report 24278378 ↗
  • InjuryAug 9, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    SURGEON REVISED AN ANATOMIC SHOULDER REPLACEMENT DUE TO SUB SCAP FAILURE AND REMOVED ALL STRYKER IMPLANTS.

    Patient problems: Joint Dislocation; No Clinical Signs, Symptoms or Conditions

    MAUDE report 19950967 ↗
  • InjuryJun 25, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "ADVERSE EVENT: : PATIENT EXPERIENCING PAIN. DIAGNOSED WITH ROTATOR CUFF FAILURE POST ARTHROPLASTY. REQUIRED INTERVENTION TO PREVENT LIFE-THREATENING ILLNESS OR INJURY, OR PERMANENT IMPAIRMENT OR DAMAGE.: YES. ORIGINAL SURGERY ¿ (ANATOMIC CONFIGURATION) DATE OF IMPLANT: (B)(6) 2014. STEM ¿ AEQUALIS ASCEND FLEX 4A STANDARD PTC HUMERAL STEM. HUMERAL HEAD- ASCEND FLEX STANDARD LOW OFFSET 46 X17 AEQUALIS (HUMERAL INDEX 6.5). GLENOID ¿ PERFORM- PEGGED M35. REVISION IMPLANTS ¿ (REVISION TO REVERSED CONFIGURATION) DATE OF REVISION SURGERY: (B)(6) 2024; STEM- RETAINED; EXPLANTATION OF THE FOLLOWING DEVICE COMPONENTS: HUMERAL HEAD- ASCEND FLEX STANDARD LOW OFFSET 46 X17 AEQUALIS (HUMERAL INDEX 6.5); GLENOID ¿ PERFORM- PEGGED M35. IMPLANTATION OF THE FOLLOWING DEVICE COMPONENTS: TRAY- HIGH OFFSET TRAY +0MM; INSERT- STANDARD 36 DIA. (+) 6MM/7.5C; GLENOID- BASEPLATE- PERFORM REVERSED GLENOID- LATERALIZED BASEPLATE (+3MM), 25MM; GLENOID- GLENOSPHERE- STANDARD 36MM DIAMETER".

    Patient problems: Implant Pain; Muscle/Tendon Damage

    MAUDE report 19608332 ↗
  • InjuryAug 22, 2023Naturally Worn; Naturally Worn

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2022 A PATIENT REQUIRED REVISION SURGERY DUE TO PERIPROSTHETIC FRACTURE AND GLENOID IMPLANT WEAR. THIS EVEN WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Limb Fracture

    MAUDE report 17599874 ↗
  • InjuryMay 26, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE PATIENT PRESENTED WITH SUBLUXATION, INSTABILITY AND PAIN. THE PATIENT UNDERWENT A REVISION PROCEDURE.

    Patient problems: Implant Pain; Subluxation

    MAUDE report 17015117 ↗
  • InjuryMay 12, 2023Osseointegration Problem; Migration; Osseointegration Problem; Migration

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2021 A PATIENT REQUIRED REVISION SURGERY DUE " ASEPTIC LOOSENING GLENOID", WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: "SINGLE STAGE REVISION.¿

    Patient problems: Osteolysis

    MAUDE report 16924907 ↗

Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices

All PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices →