Vermed IP-Set 6V RT ADULT-USRecalls & reported problems
Graphic Controls Acquisition Corp · SET OF 6V PRE-WIRED RT ADULT ELECTRODES · Class 2
All models of Vermed (8)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier.
5 other recalls cover devices cleared under the same FDA submission (K101685); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Mar 15, 2022Class IITerminated
Instructions for Use (IFU) (Instructions for Use) indicate compliance with ANSI/AAMI EC53:2013/(R)2020 ECG trunk cables and patient leadwires. Section 5.3.9 of the standard requires the device to withstand, without breakdown , an application of, 5,000 V d.c. when used with a defibrillator at a voltage above its maximum threshold, Claravue does not meet the specification and delivers an inefficient electrical charge which may result in an ineffective defibrillation.
Z-0939-2022 · Root cause: Device Design · Recall details · FDA record ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K101685. One submission often covers many models, so check the product and lot details in each record.
- Z-0940-2022 · Mar 15, 2022 · TerminatedCLARAVUE Pre-wired Electrode - IP SET 5V RT ADULT Model: 32028781 50604-US
- Z-0938-2022 · Mar 15, 2022 · TerminatedCLARAVUE Pre-wired Electrode - IP SET 12 RT ADULT-US Model: 32028779 50602-US
- Z-0936-2022 · Mar 15, 2022 · TerminatedCLARAVUE Pre-wired Electrode - IP SET M3 RT ADULT-US Model: 32028777 50600 US
- Z-0937-2022 · Mar 15, 2022 · TerminatedCLARAVUE Pre-wired Electrode - IP SET M5 RT ADULT-US Model: 32028778 50601-US
- Z-0935-2022 · Mar 15, 2022 · TerminatedCLARAVUE Pre-wired Electrode IP-SET N3 - PEDIATRIC-US Model: 32028776 50401-US
Other Electrode, Electrocardiograph devices
- Vermed A10091-30Graphic Controls Acquisition Corp · Electrode, Electrocardiograph132 reports
- 3M™ 22283m Company · Electrode, electrocardiograph2 recalls0 reports
- 3M™ Red Dot™ 22283m Company · Electrode, electrocardiograph1 recall4 reports
- Vital Signs™ 2464AAO-20AirLife Finland Oy · Electrode, electrocardiograph51 reports
- Vermed IP-Set M5 RT Adult-USGraphic Controls Acquisition Corp · Electrode, Electrocardiograph1 recall0 reports
- Vermed IP-Set 5V RT Adult-USGraphic Controls Acquisition Corp · Electrode, Electrocardiograph1 recall0 reports
- Vermed IP-Set N3-Pediatric-USGraphic Controls Acquisition Corp · Electrode, Electrocardiograph1 recall0 reports
- Vermed IP-Set M3 RT Adult-USGraphic Controls Acquisition Corp · Electrode, Electrocardiograph1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page