TRIWAY N02 00011Recalls & reported problems
In2bones · HITTING PLATE TRIWAY ARTHRODESIS NAIL · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03760225717950), received between Dec 3, 2020 and Dec 3, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Difficult to Advance1
- Difficult to Insert1
- Failure to Align1
- Improper or Incorrect Procedure or Method1
- Off-Label Use1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 3, 2020Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method
ANKLE SURGERY: THE TRIWAY(R) TTC ARTHRODESIS SYSTEM IS INTENDED FOR USE IN TIBIOTALOCALCANEAL ARTHRODESIS AND TREATMENT OF TRAUMA TO THE HINDFOOT AND DISTAL TIBIA. EXAMPLES INCLUDE: - POST-TRAUMATIC AND DEGENERATIVE ARTHRITIS INVOLVING BOTH ANKLE AND SUBTALAR JOINTS - RHEUMATOID ARTHRITIS WITH SEVERE DEFORMITY - REVISION OF FAILED ANKLE ARTHRODESIS WITH SUBTALAR INVOLVEMENT OR WITH INSUFFICIENT TALAR BODY - REVISION OF FAILED TOTAL ANKLE ARTHROPLASTY WITH SUBTALAR INTRUSION - TALAR DEFICIENCY CONDITIONS, INCLUDING AVASCULAR NECROSIS (REQUIRING A TIBIOCALCANEAL ARTHRODESIS) - NEUROARTHROPATHY OR NEUROMUSCULAR DEFORMITY OR OTHER NEUROMUSCULAR DISEASE WITH SEVERE DEFORMITY OR INSTABILITY OF THE ANKLE, INCLUDING CHARCOT FOOT - SEVERE PILON FRACTURES WITH TRAUMA TO THE SUBTALAR JOINT - MALUNITED TIBIAL PILON FRACTURES THE IN2BONES TRIWAY(R) TTC ARTHRODESIS NAIL HAS TO BE FIXED WITH THE ASSOCIATED: TIBIAL FIXATION USING COTTER SCREWS DIAMETER 5.0MM ; TALAR FIXATION USING COTTER SCREWS DIAMETER 5.0MM ; CALCANEUS FIXATION USING COTTER SCREWS DIAMETER 5.0MM. THE ADDITION OF AN IBS" 6.5MM COMPRESSION SCREW THROUGH THE SUBTALAR JOINT AND THROUGH THE NAIL IS REQUIRED. ALL SCREWS ARE INTENDED T
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10940182 ↗MalfunctionDec 3, 2020Break; Difficult to Insert; Off-Label Use; Failure to Align; Difficult to Advance
ANKLE SURGERY: THE TRIWAY TTC ARTHRODESIS SYSTEM IS INTENDED FOR USE IN TIBIOTALOCALCANEAL ARTHRODESIS AND TREATMENT OF TRAUMA TO THE HINDFOOT AND DISTAL TIBIA. EXAMPLES INCLUDE: POST-TRAUMATIC AND DEGENERATIVE ARTHRITIS INVOLVING BOTH ANKLE AND SUBTALAR JOINTS. RHEUMATOID ARTHRITIS WITH SEVERE DEFORMITY. REVISION OF FAILED ANKLE ARTHRODESIS WITH SUBTALAR INVOLVEMENT OR WITH INSUFFICIENT TALAR BODY. REVISION OF FAILED TOTAL ANKLE ARTHROPLASTY WITH SUBTALAR INTRUSION. TALAR DEFICIENCY CONDITIONS, INCLUDING AVASCULAR NECROSIS (REQUIRING A TIBIOCALCANEAL ARTHRODESIS). NEUROARTHROPATHY OR NEUROMUSCULAR DEFORMITY OR OTHER NEUROMUSCULAR DISEASE WITH SEVERE DEFORMITY OR INSTABILITY OF THE ANKLE, INCLUDING CHARCOT FOOT. SEVERE PILON FRACTURES WITH TRAUMA TO THE SUBTALAR JOINT. MALUNITED TIBIAL PILON FRACTURES THE IN2BONES TRIWAY¿ TTC ARTHRODESIS NAIL HAS TO BE FIXED WITH THE ASSOCIATED: TIBIAL FIXATION USING COTTER SCREWS DIAMETER 5.0MM ; TALAR FIXATION USING COTTER SCREWS DIAMETER 5.0MM ; CALCANEUS FIXATION USING COTTER SCREWS DIAMETER 5.0MM. THE ADDITION OF AN IBS" 6.5MM COMPRESSION SCREW THROUGH THE SUBTALAR JOINT AND THROUGH THE NAIL IS REQUIRED. ALL SCREWS ARE INTENDED TO BE IMPLATED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10940169 ↗
Other Guide, Surgical, Instrument devices
- NA 03.037.017Synthes GmbH · Guide, surgical, instrument346 reports
- EVOS 71174934Smith & Nephew, Inc. · Guide, surgical, instrument149 reports
- LCP 323.042Synthes GmbH · Guide, surgical, instrument129 reports
- DJO SURGICAL 342-10-705Encore Medical, L.P. · Guide, Surgical, Instrument1 recall51 reports
- DJO SURGICAL 341-10-707Encore Medical, L.P. · Guide, Surgical, Instrument81 reports
- NA 03.010.404Synthes GmbH · Guide, surgical, instrument73 reports
- DJO SURGICAL 341-14-708Encore Medical, L.P. · Guide, Surgical, Instrument1 recall22 reports
- DJO SURGICAL 341-10-711Encore Medical, L.P. · Guide, Surgical, Instrument1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page