Bicarbonate liquid 3289923190Recalls & reported problems
Roche Diagnostics GmbH · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04015630919352), received between Nov 22, 2023 and Sep 3, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings1
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 3, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE INITIAL REPORTER STATED THEY RECEIVED QUESTIONABLE RESULTS FOR TWO SAMPLES COLLECTED FROM THE SAME PATIENT AND TESTED WITH BICARBONATE LIQUID ON A COBAS 6000 C501 MODULE. IT IS ALLEGED THAT THE PATIENT'S SAMPLES CONTAIN AN INTERFERING FACTOR AGAINST A COMPONENT OF THE BICARBONATE ASSAY. THE FIRST SAMPLE FROM THE PATIENT RESULTED IN BICARBONATE VALUES OF 7.1 MMOL/L AND 7.1 MMOL/L. A RE-COLLECTION OF THE PATIENT WAS REQUESTED. A SECOND SAMPLE (PLASMA) WAS COLLECTED FROM THE PATIENT AND TESTED ON (B)(6) 2025, RESULTING IN BICARBONATE VALUES OF 2.9 MMOL/L AND 2.3 MMOL/L. THIS SAME PLASMA SAMPLE WAS REPEATED ON AN UNKNOWN BLOOD GAS ANALYZER, RESULTING IN A BICARBONATE VALUE OF 22.6 MMOL/L. THE WHOLE BLOOD TUBE FROM THE SAME COLLECTION WAS ALSO TESTED ON THE BLOOD GAS ANALYZER, RESULTING IN A BICARBONATE VALUE OF 24.4 MMOL/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22955113 ↗MalfunctionNov 22, 2023Low Test Results; Low Test Results
THE INITIAL REPORTER STATED THEY RECEIVED QUESTIONABLE RESULTS FOR FOUR SAMPLES FROM THE SAME PATIENT TESTED WITH CO2-L (BICARBONATE) ON A COBAS 8000 COBAS C 502 MODULE. THE RESULTS OBTAINED FOR THE PATIENT DID NOT FIT THE PATIENT'S DIAGNOSIS OF ACIDOSIS. THE FIRST SAMPLE RESULTED IN A BICARBONATE VALUE OF 4 MMOL/L ON (B)(6) 2023. THE SECOND SAMPLE RESULTED IN A BICARBONATE VALUE OF 4 MMOL/L ON (B)(6) 2023. THE THIRD SAMPLE RESULTED IN A BICARBONATE VALUE OF 4 MMOL/L ON (B)(6) 2023. THE FOURTH SAMPLE RESULTED IN A BICARBONATE VALUE OF 6.1 MMOL/L ON (B)(6) 2023. ON AN UNKNOWN DATE, A SAMPLE FROM THE PATIENT WAS TESTED ON AN UNKNOWN BLOOD GAS ANALYZER, RESULTING IN THE FOLLOWING VALUES: PH = 7.35, PACO2 = 49 (NO UNITS PROVIDED), PAO2 = 88 (NO UNITS PROVIDED), BICARBONATE = 26 MMOL/L, LACTATE = 2.1 (NO UNITS PROVIDED).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18194372 ↗
Other ENZYMATIC, CARBON-DIOXIDE devices
- AU OSR6237Beckman Coulter, Inc. · Enzymatic, Carbon-Dioxide2 recalls1 report
- AU OSR6637Beckman Coulter, Inc. · Enzymatic, Carbon-Dioxide2 recalls0 reports
- AU OSR6137Beckman Coulter, Inc. · Enzymatic, Carbon-Dioxide2 recalls0 reports
- Alinity 07P7220Abbott GmbH · ENZYMATIC, CARBON-DIOXIDE90 reports
- VITROS 8262396Ortho-Clinical Diagnostics, Inc. · ENZYMATIC, CARBON-DIOXIDE1 recall0 reports
- ARCHITECT 3L80-22Abbott GmbH · ENZYMATIC, CARBON-DIOXIDE31 reports
- Atellica CH CO2_c 11097521Siemens Healthcare Diagnostics Inc. · ENZYMATIC, CARBON-DIOXIDE21 reports
- Dimension Vista® Flex® reagent cartridge CO2 10445163Siemens Healthcare Diagnostics Inc. · ENZYMATIC, CARBON-DIOXIDE15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page